684517
27
Zoom out
Zoom in
Previous page
1/47
Next page
27
ENGLISH
Installing the unit
IMPORTANT: When installing the unit, always remember to connectrst the refrigerant tubes, then the electrical lines.
Always disassemble the electric lines before the refrigerant tubes.

Upon receipt, inspect the product to verify that it has not been damaged during transport.
If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the
installer or the authorized technician has collected the material from the retailer.)

After completing the installation, always carry out a functional test and provide the instructions on how to operate the air
conditioner to the user. If using a multi system, carry out a functional test as described in the installation manual supplied
with the outdoor unit.

Do not use the air conditioner in environments with hazardous substances or close to equipment that release free ames to
avoid the occurrence ofres, explosions or injuries.

To prevent injury when accidentally touching the indoor unit fan, install the indoor unit at least 2.5m above the oor.
The air conditioner should be used only for the applications for which it has been designed : the indoor unit is not suitable
to be installed in areas used for laundry.
Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility
from both sides or ability to perform routine maintenance and repairs. The unitscomponents must be accessible and that
can be disassembled in conditions of complete safety either for people or things.
For this reason, where it is not observed as indicated into the Installation Manual, the cost necessary to reach and repair the
unit (in safety, as required by current regulations in force) with slings, trucks, scaolding or any other means of elevation
won’t be considered in-warranty and charged to end user.
Power supply line, fuse or circuit breaker

Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in
compliance with current local safety standards.

Always verify that a suitable grounding connection is available.
Verify that the voltage and frequency of the power supply comply with the specications and that the installed power is
sucient to ensure the operation of any other domestic appliance connected to the same electric lines.
Always verify that the cut-oand protection switches are suitably dimensioned.
Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring
diagram included in the manual.
Always verify that electric connections (cable entry, section of leads, protections…) are compliant with the electric
specications and with the instructions provided in the wiring scheme.
Always verify that all connections comply with the standards applicable to the installation of air conditioners.
Indoor unit
Where airow is not blocked
Where cool air can be distributed throughout the room
Install the refrigerant piping length and the height dierence of both indoor and outdoor units as indicated in the
installation diagram
Wall that prevents vibration and is strong enough to hold the product weight
Out of the direct sunlight
1m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)
As far away as possible from the uorescent and incandescent lights (so that the remote controller can be operated well)
A place where the air lter can be replaced easily
Choosing the installation location
Maldives ET_AR09FSFP@_IBIM_DB68-03376A_EN_2.indd 27 2012-12-3 18:54:33
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Samsung AR12FSFP Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Samsung AR12FSFP Series in the language / languages: English as an attachment in your email.

The manual is 10,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info