735177
60
Zoom out
Zoom in
Previous page
1/76
Next page
02 VS10W and VS10B Installer Manual
Contents
1 x Installer / User manual VS10W VS10BFixing screws
Contents
Box contents
Introduction
Product Compliance
System options overview
Installation
Parameter Settings
Error Codes
User Guide
Installers notes
Warranty
Box Contents
Icons used in this manual:
Safety
Important info
Your benet
For latest PDF installation guide please
go to www.salus-controls.com
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:48
Product Compliance & Safety Information
INTRODUCTION
Thank you for purchasing
the SALUS 4 in 1 digital room thermostat
VS10. To maximise the features the
unit, it should be used with
the SALUS Wiring Centre KL10.
The unit can be congured to be a
Programmable Thermostat (PRT), Group Control
Thermostat, Group Thermostat or hot water
timer. The units can communicate with each
other (including VS05 Dial Thermostat) when
connected to the wiring centre and using the
communication connections. More information
can be found on pages 9 and 10.
Product Compliance
This product is CE compliant and meets the
following EC Directives Electro-Magnetic
Compatibility directive 2004/108/EC
Low voltage Directive 2006/95/EC
Safety Information
Use in accordance with the regulations
The SALUS VS10 is to be used for
for room control of heating and hot water
systems inside the house.
SALUS Wiring Centre KL10
We hope you enjoy this product...
VS10W and VS10B Installer Manual 03
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:48
Product Compliance & Safety Information
Sources of danger
The thermostat must be disconnected from mains supply
before removing the cover.
Emergency
Switch o the voltage to the individual thermostat wring
centre or complete system.
Installer parameter settings
The SALUS VS10 is equipped with installer
parameter section (see page 40) this must only
be entered by the installer or competent
person. Changing these parameters can have a
serious eect on your heating system
For the installer
Please enter any parameter changes in the
installer notes section (pages 72 - 74)
230V AC
04 VS10W and VS10B Installer Manual
These instructions are applicable to the SALUS model
stated on the front cover of this manual only.
Warning
This product must be tted by a competent person, and
installation must comply with the guidance, standards
and regulations applicable to the city, country or state
where the product is installed. Failure to comply with the
requirements of the relevant guidance, standards and
regulations could lead to injury, death or prosecution.
Warning
Always isolate the AC Mains supply before
installing or working on any components that
require 230 VAC 50Hz supply.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:48
VS10W and VS10B Installer Manual 05
System Overview - Conguration Options
Programmable Room
Thermostat (PRT)
The unit can be
congured to either
one of the following
1
UFH Manifold
Wiring Centre
Radiator
Boiler
Hot Water
Group Control
Thermostat
2
Group
Thermostat
3
Timer
4
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:48
System Overview - Conguration Options
06 VS10W and VS10B Installer Manual
Programmable Room Thermostat (PRT)
When congured for PRT (see page 31) it mainly works by itself and allows the user to have separate Time and
Temperature control of each zone on the wiring centre. Features like Vacation , Party frost mode have to set on
each individual thermostat. The PRT can be congured for global Heat/Cool system changeover if your system
supports this. This is achieved from a switched input from the wiring centre (see note 6 from the wiring center
installation guide). Communication Connection (see page 13) is required to use heat/cool changeover function
Group Control Thermostat
When congured for a group control thermostat (see page 33) this allows central control of up to 7 group
thermostats see below, there can be a maximum of 2 groups per 8 zone wiring centre. Permanent temperature
override, Holiday, Party, Frost modes, can be selected centrally from the Group Control Thermostat. Holiday will
also be applied to a timer if applicable. Communication connections (see page 13) are required for grouping
the group thermostats. Thermostats can be also globally changed from heating to cooling thermostats if you
system supports this by using the switched input connection on the WC (see note 6 from the wiring center
installation guide) along with the communications connections mentioned above
Group Thermostat
When congured for Group thermostat (see page 36) and in group mode the group thermostat will follow the
time schedule and any override modes of the group thermostat. The Group thermostat can have its own
programd temperatures, manual override and also be removed from the group temporarily or permanently.
Communication connections required (see page 13).
Timer
When congured to timer (see pages 32 & 34) the unit will operate as a timer with no temp control. This can be
used for example hot water control. The timer will also follow Holiday mode from the group control thermostat
if applicable, communication connections required for this group function.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:48
System Overview - Cables
Power and Switching Cable – used to
power thermostats and drive output
Grouping and Communication cable
Communication cable can be used when units are used as individual PRT's for heat/cool
changeover. Please refer to page 13 and note 5 on the wiring centre installation guide.
While the thermostats can function as stand alone
Programmable or Timer’s, Installing this Optional inexpensive
Communication Cable allows the thermostats to communicate
with each other. This allows the thermostat to assume
convenient remote control of groups of thermostats. Bringing
central control of features such as Time control, Holiday & Party
functions as well as frost control. The individual group members
can leave or re-enter group control at the push of a button
Cable size 1.5mm 3 core for L,N,SL and 0.5mm twin for the communication.
VS10W and VS10B Installer Manual 07
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
System Overview - Options
Option 1 - Page 09
Option 2 - Page 10
Option 3 - Page 10
The systems below although not exhaustive show the main options. The
maximum number of groups per KL10 wiring centre is two. The group
selection communication cable must correspond to the group terminals
on the KL10 WC. Please refer to note 5 on the KL10 installation guide.
Group 1 Group 2
Group 1
Group 2
All Digital Variants can be
congured from VS10. Groups
must have a group control
thermostat. 1 or 2 Groups can be
used per wiring centre. HW Timer
can be stand alone or part of a
group. If using HW Timer as part
of a group it must be in group 1.
08 VS10W and VS10B Installer Manual
Option 2 - Unit is congured as a Group Control Thermostat used to control a group(s) of Dial Stat(s)
Option 3 - Unit is congured as a Group Control Thermostat used to control a group(s) of Digital Stat(s) congured as group thermostats.
Option 1 - Unit is congured as individual PRT.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
System Overview - Grouping and Communication
FUNCTION PRT USING COMMUNICATION
CONNECTION - PRT
Individual Room Control 4 4
Individual Holiday Function 4 4
Individual Party Function 4 4
Individual Heating Program 4 4
Individual Frost Function 4 4
Group Holiday including HW 6 6
Group Party 6 6
Group Heating Program 6 6
Group Permanent Override 6 6
Group Temporary Override 6 6
Heat/Cool changeover 6 4
Note: The communication connection is only used for heat/cool changeover when using
units congured to PRT’s and using the relevant connection on the KL10 Wiring Centre.
Please refer to note 6 on Wiring Centre installation guide.
Option 1 - Page 31
VS10W and VS10B Installer Manual 09
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
System Overview - Grouping and Communication
FUNCTION PRT USING COMMUNICATION
CONNECTION - GROUP CONTROL
Individual Room Control 4 4
Individual Holiday Function 4 4
Individual Party Function 4 4
Individual Heating Program 4 4
Individual Frost Function 4 4
Group Holiday including HW 6 4
Group Party 6 4
Group Heating Program 6 4
Group Permanent Override 6 4
Group Temporary Override 6 4
Heat/Cool changeover 6 4
Note HW timer will only use HOLIDAY function when the communication connection
is used. Also the HW timer must be connected to GROUP 1 communication terminals
on wiring centre. See note 8 on Wiring Centre installation guide.
Option 2 - Page 33 Option 3 - Page 35
10 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
System Overview - Hot Water Option
When the unit is congured as a hot water timer (see page 34)
there are two methods of connecting the cylinder thermostat
Unit congured to
Hot Water Timer.
Cylinder thermostat options
1 Connected direct to WC (Default)
2 Connected direct to VS10 (requires additional
parameter change. See page 40)
VS10W and VS10B Installer Manual 11
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
System Overview - Hot Water Option
1 Connected direct to WC (Default) 2 Connected direct to VS10
(requires additional parameter change see page 40)
For convenience there is a unique built in option allowing the cylinder
thermostat to be connected to either the HW Timer or Wiring Centre.
Please refer to note 1 on Wiring Centre guide and page 18 for more information.
12 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
Installation – Terminal Connections
Understanding your terminal connections
Rear of unit
Communication Terms 12VDC
Two wire twisted pair can be
used for Grouping Functions
between PRT, Group Control
Thermostat, Group Thermostat
and HW Timer.
Power Terminals 230 Vac
Used for supplying power to the
unit and switched output.
Sensor Terminals
Can be used for external AIR,
Floor sensor when congured
as thermostat. Can also be
used for Cylinder thermostat
when congured for HW.
1
3
2
1 2 3
VS10W and VS10B Installer Manual 13
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
Carefully remove the front housing.
Installation – Thermostat Mounting
1 3
2
60mm
14 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
Installation – Thermostat Mounting
Not to be positioned on an exterior wall.
Mounting position and installation
To ensure trouble free operation and ecient control, the unit is best positioned
in a draft free area and at 130cm from the oor. Do not position the thermostat
near any heat source, behind curtains, direct sunlight or an area of high humidity.
VS10W and VS10B Installer Manual 15
INSTALLATION
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:49
Installation - Graphics Key
30 VS10W and VS10B Installer Manual
Press once
Press x amount of times
Hold for ve seconds
Flashing
xx
Short press to save and
long press to save and exit
Short press to back up
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:51
Option 1 - Individual Programmable thermostat setup
VS10W and VS10B Installer Manual 31
Long press to exit
to home screen
or continue to
change device
settings. Refer to
page 33.
Short press on
to back up.
Use to
change to 2.
PRT with no communication*
*Select S03 setting 0 if communication is required for global heat/cool changeover.
Your system must support this and the communication connection must be used. See page 13.
SYSTEM OPTION 1
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:51
Option 1 - Hot Water Timer (Optional ) Conguration
Long press to exit
to home screen
or continue to
change device
settings. Refer to
page 40.
Hot water with no communication.
32 VS10W and VS10B Installer Manual
Use to
change to 2.
Use to
change to 2.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:51
Option 2 - Thermostat Conguration
Group
Control
Thermostat
VS10W and VS10B Installer Manual 33
Long press to
exit to home
screen or
continue to
change device
settings. Refer
to page 40.
Communication
connection
required for this
setting.
SYSTEM OPTION 2
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:51
Option 2 - Hot Water Timer (Optional) Conguration
34 VS10W and VS10B Installer Manual
Long press to exit
to home screen
or continue to
change device
settings. Refer to
page 40.
Communication
connection
required for this
setting.
Use to
change to 2.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:51
Option 3 - Thermostat Conguration
VS10W and VS10B Installer Manual 35
SYSTEM OPTION 3
Group
Control
Thermostat
Long press to
exit to home
screen or
continue to
change device
settings. Refer
to page 40.
Communication
connection
required for this
setting.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
Installation - Technical Detail
Model VS10W/ VS10B
Type Electronic programmable room thermostat, digital room
thermostat and hot water timer designed for 230V AC applications
Programming Modes User selectable for 5/2, ALL and Individual day options
Program Number 1-6 Selectable
Modes Party, Vacation, Program and Frost
Override Permanent and temporary
Frost Protection 5ºC Adjustable
Power Source 230V AC 50Hz
Rating 3 Amp
Communication Bus 12V DC
Temperature Scale 5 to 35ºC, tolerance 0.5ºC
Heat/Cool Global changeover using communication bus and external input
to the wiring centre
Sensor Air or oor protection. Cylinder thermostat when congured for
hot water timer.
Device Parameters See page xx for full list of functions
Operating Temperature 0 to 50ºC
Storage Temperature -20 to 60ºC
44 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:52
User Guide - Temporary Override
Use the up or down
arrow key to view
your program set
temperature.
The temporary
override is applicable
to the thermostat
being changed only.
Use the up or down
arrow key to adjust
the temperature to
the setting you
desire.
Temporary override allows you to increase the
temperature or decrease it to the desired setting
until it reverts back on the next program time.
58 VS10W and VS10B Installer Manual
PRT, Group Control Thermostat and Group Thermostat
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Temporary Override
To cancel temporary override press or
See below.
VS10W and VS10B Installer Manual 59
PRT, Group Control Thermostat and Group Thermostat
Conrm the
temporary set
temperature.
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:53
User Guide - Permanent Override
To cancel permanent override select
See below.
Permanent override in a control group
thermostat will also aect the group
thermostats onless they are removed from
the group. See page 64.
Move from
to
Use the up or
down arrow key to
view your set
temperature. See
page 58.
To adjust your
permanent
override
temperature,
follow the steps
on page 58.
Repeat for
if required
60 VS10W and VS10B Installer Manual
PRT and Group Control Thermostat
Setting permanent low temperature
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Party Mode
The party mode is
an option that
enables
temperature
for a period of
time you select
up to 9hr 50min.
Use the right
arrow to select
the party mode.
Use the up
arrow to select
the hr/min.
Press tick to
conrm and
it will start to
count down .
Party Mode set in
a Control Group
Thermostat will
also aect group
thermostats
unless they are
removed from the
group.
See page 64.
VS10W and VS10B Installer Manual 61
USER GUIDE
PRT and Group Control Thermostat
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Holiday Mode
Use the right
arrow to select
the holiday mode.
Use the up arrow
to select how
many days to be
o for .
Press tick to
conrm and it will
start the holiday
count down.
62 VS10W and VS10B Installer Manual
Holiday set in a
Control Group
Thermostat will
also aect group
thermostats
unless they are
removed from the
group.
See page 64.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Frost Protection
Use the right
arrow to select
the frost mode.
Use the up arrow
to select the
frost protection
temperature.
Press tick to
conrm the
temperature
that has been
set to.
VS10W and VS10B Installer Manual 63
Frost protection set
in a Control Group
Thermostat will
also aect group
thermostats unless
they are removed
from the group.
See page 64.
Frost protection is
not available in
cooling. Moving the
to this
position in cooling
will switch the
thermostat to o.
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Group Thermostat Overview
When a group thermostat
is in it will follow
the mode status of the
group control thermostat.
When a group
thermostat is in
and the group control
thermostat is in
or then
the group thermostat
will follow this mode.
or will be
displayed.
The group thermostat
has now left the group
and is in permanent
To adjust the set
temperature, please
refer to page xx.
The group thermostat
has now left the group
and is in permanent
To adjust the set
temperature, please
refer to page xx.
64 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Group Thermostat Overview
The group thermostat
has now left the group
and is in permanent
To adjust the set
temperature, please
refer to page xx.
The group thermostat
has now left the group
and is in permanent
To adjust the set
temperature, please
refer to page xx.
The group thermostat
has been returned to
it will follow the mode
status of the group
control thermostat.
VS10W and VS10B Installer Manual 65
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Hot Water (Optional) Mode Selection
66 VS10W and VS10B Installer Manual
2
3
Mode selection
Hot water will follow
Holiday mode from the
group control
thermostat.
will be displayed.
When is
selected, the hot
water timer will follow
the program schedule.
See page 68.
Hot water will be
on once per day.
Hot water will be
continuously on.
Hot water will be
continuously o.
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Hot Water Boost
VS10W and VS10B Installer Manual 67
USER GUIDE
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Default Hot Water Schedule
12.00
6.00 8.00 18.00 22.00
ON ON
OFFOFF OFF
12.00 6.00 8.00 18.00 22.00
Saturday and Sunday
Monday to Friday
ON ON
OFFOFF OFF
Your hot water timer comes preset with the times below.
These can be adjusted. See next page.
68 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:54
User Guide - Setting Hot Water Times
VS10W and VS10B Installer Manual 69
USER GUIDE
5/2
7 Days
Individual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
User Guide - Setting Hot Water Times
70 VS10W and VS10B Installer Manual
Repeat these steps for
programs
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
User Guide - Setting Hot Water Times
VS10W and VS10B Installer Manual 71
USER GUIDE
Repeat these steps for
programs
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
Installer Notes
72 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
Installer Notes
VS10W and VS10B Installer Manual 73
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
Installer Notes
74 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall
perform in accordance with its specication, for a period of ve years from the date of installation. SALUS
Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
Customer Name: .............................................................................................................................
Customer Address: ..........................................................................................................................
............................................................................... Post Code: ........................................................
Tel No: ........................................................ Email: .........................................................................
Engineers Company: .......................................................................................................................
Tel No: ......................................................... Email: ........................................................................
Instalation Date: ..............................................................................................................................
Engineers Name: ............................................................................................................................
Engineers Signature: .......................................................................................................................
VS10W and VS10B Installer Manual 75
Warranty
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
www.salus-controls.com
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.
SALES: T: +44 0 1226 323961
E: sales@salus-tech.com
TECHNICAL: T: +44 0 1226 323961
E: tech@salus-tech.com
Issue Date: April 2014 For PDF Installation guide please go to www.salus-controls.com
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specication, design and materials of products listed in this brochure without prior notice.
SALUS Controls is a member of the Computime Group
00086/2
iT600 VS10W - VS10B Installer - User Manual 022_Layout 1 22/06/2014 18:55
60


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Salus VS10W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Salus VS10W in the language / languages: English as an attachment in your email.

The manual is 14,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Salus VS10W

Salus VS10W User Manual - German - 76 pages

Salus VS10W User Manual - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info