TESTING THE RF TRANSMISSION
1. Press the UP button on the thermostat until the set point
temperature is higher than room temperature by a few degrees.
2. Wait for a few seconds. The boiler on (heat call) indicator should
appear on the bottom left of the LCD on the thermostat.
3. Check the LED on the receiver unit - it should be illuminated.
4. Press the DOWN button to adjust the set point temperature to be lower
than room temperature.
5. Wait for a few seconds, and the boiler on (heat call) indicator should
disappear and the LED should go out.
OTHER FUNCTIONS AND CONTROLS
Backlight
The backlight of the RT505TX is switched on automatically whenever any
of the keys are pressed. The backlight will remain illuminated for
approximately 5 seconds after the last key press, except if you are
changing settings within the Clock, Programme or Temporary Override
modes – in this case, the backlight will remain illuminated throughout the
setting change process. The backlight will not illuminate if the RT505TX
battery is low.
Battery Status
The RT505TX checks the battery voltage frequently during normal
operation. If the battery voltage is sensed as being low (this is normally
when the battery voltage falls to a level of around 2.6V), the low battery
indicator will be displayed on the screen.
Although the programmable thermostat will continue to operate
normally at this stage, you should replace the batteries as soon as possible
to prevent any possible operating problems.
Reset Button
The Reset Button is provided as a way to restore the programmable
thermostat to its default factory settings. Pressing this button will delete
any previously entered settings.
RT505TX INSTRUCTION MANUAL
15
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 15
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Salus RT505TX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Salus RT505TX in the language / languages: English as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info