Installation and Wiring Guide KL08RF
www.salus-controls.com Technical Helpline +44 (0) 1226 323 961
Installing and Connecting the KL08RF
Use the KL08RF wireless wiring centre to simply and safely connect thermostats and corresponding
thermal actuators. The KL08RF connects to the wireless network through the UG600/UGE600 universal
gateway for the internet systems and through the CO10RF coordinator for the non internet systems.
One universal gateway can support up to 100 devices and one coordinator can support up to nine
wiring centres, which means that if you buy more than one wiring centre, you will only need one
univeral gateway or one of the included coordinators. Keep the other coordinators in a safe place
as spares. Install the KL08RF only in dry and closed interior rooms. Relative air humidity in the room
may not exceed 95%. Clean the KL08RF only with a dry and soft cloth. Do not use solvents or aggressive
cleaning agents.
Remove the plastic
cover. Open (and
close) the four
white screws with a
quarter turn only. Note
that screws on opposite
sides turn in the opposite
direction.
2
Remove the
white terminal
connection board
3
Attach the back of
the KL08RF to the
DIN rail or wall.
4
Cut the power and
device cable to
length.
6
Push the power
wires into the
round power holes.
Attach the white
strain-relief using
the two screws to
secure the power wires.
8
9
Push in the Pump wires at the bottom
right of the KL08RF for volt-free pump
switching.
For 230V connections follow the wiring
diagram from the first page.
10
Push in the Boiler wires at the bottom
right of the KL08RF for volt-free boiler
switching. When a zone calls for heat,
the boiler switch closes causing the
boiler to run.
11
Push in the CO wires at the bottom
right of the KL08RF for volt-free
heating/cooling changeover switching.
An open switch is for heating (red LED).
A closed switch is for cooling (blue LED).
Note: Create the connections only for a
cooling system.
12
Push in the Dew Point wires at the
bottom right of the KL08RF for volt-free
humidity sensing.
13
Attach the red strain-relieving strip
using the three screws to secure the
pump, boiler, CO, and dew point wires
to the bottom side of the KL08RF.
14
Set the boiler delay, wireless, and thermal
actuator jumpers at the top right of the
KL08RF.
Jumper Settings/Positions for Pump/Boiler On/Off Delay
The pump/boiler on delay and the pump off
delay are fixed at 3 minutes in the software
and at 0 in the terminal. The default setting for
the boiler off delay is also 0 minutes, but can
be changed to 15 minutes. To do this, carefully
remove the jumper and re-insert it in the other
position as shown below:
Press the Reset button to complete this action.
Antenna
The default setting for the antenna is internal
(INT). To change this setting to external (EXT),
carefully remove the jumper and re-insert it in
the other position as shown below:
Press the Reset button to complete this action.
Type of Actuator
The default setting for the type of actuator is
normally closed (NC). To change this setting
to normally open (NO), carefully remove the
jumper and re-insert it in the other position as
shown below.
Press the Reset button to complete this action.
15
LED indications
Name Colour Meaning
Power
KL08RF is supplied with 230V power
G1
Wireless network activity on group 1 thermostats
G2
Wireless network activity on group 2 thermostats
Network Status
KL08RF is waiting to pair
KL08RF is connected to the wireless network
Zone 1 actuators
Demand from group 1, zone 1 thermostat: actuator open
Zone 2 actuators
Demand from group 1, zone 2 thermostat: actuator open
Zone 3 actuators
Demand from group 1, zone 3 thermostat: actuator open
Zone 4 actuators
Demand from group 1, zone 4 thermostat: actuator open
Zone 5 actuators
Demand from group 2, zone 1 thermostat: actuator open
Zone 6 actuators
Demand from group 2, zone 2 thermostat: actuator open
Zone 7 actuators
Demand from group 2, zone 3 thermostat: actuator open
Zone 8 actuators
Demand from group 2, zone 4 thermostat: actuator open
Pump
Pump on
Boiler
Boiler on
CO
Heating mode
Cooling mode
Push the thermal actuator wires into
the round holes at the bottom of the
KL08RF. You can connect up to three
actuators in each zone.
Make sure there is a fuse in the fuse
holder.
16
If you set up a non internet system, plug
in the CO10RF coordinator.
Reattach the
plastic cover.
Switch on mains
power supply to
the unit. The red
LED comes on.
18
7
Device
Power/Thermostat
50mm
110mm
10mm
10mm
If you need to install the optional
external antenna and have set the
Wireless jumpers to EXT:
a. Disconnect power.
b. Remove the protective
cap from the antenna
connection on the
underside of the
KL08RF.
c. Screw the antenna into
the KL08RF.
d. Press the Reset button
to complete this action.
e. Reconnect power. The
KL08RF will now use
the external antenna
and not the internal
antenna.
17
Heating mode
Cooling mode
5
Reattach the
white terminal
connection board
1
19
Coordinator
Connecting the KL08RF (s) to the ZigBee Wireless Network
1. On powering up the KL08RF, actuator LEDs will light up green then go o, then the
Network Status LED ashes green.
2. Press and hold the button on the coordinator for ve seconds. The button ashes red to
indicate the coordinator is ready to pair. The Network Status LED on the KL08RF goes steady
green when connected.
3. Repeat the process for every KL08RF in the system. Note that one coordinator can support
up to nine KL08RFs.
4. To identify your KL08RF (WC) number press Pair for one second. The LED on the zone
number lights green: WC -1=Zone 1, WC-3=Zone 1, 2, 3, and so on. The Network Status LED is used to identify WC-9
5. To pair your Salus thermostats, see your thermostat manual.
6. Press the coordinator button for ve seconds until the LED ashes steady red.
Note: To restore the KL08RF back to factory default settings at any time, press and hold the pair button on the KL08RF for 15
seconds. The G1 and G2 LEDs turn from ashing red to solid red then go o. After that please press the Reset button once.
Checking the System Conguration and Communication
Press and hold the coordinator button for one second. All devices connected to the system ash. To stop checking, press and
hold the coordinator button again for one second.
Press and hold the Pair button on the WC for ve seconds. All devices connected to the KL08RF will ash. To stop checking,
press and hold the Pair button again for ve seconds.
Deleting all Devices from the Wireless Network
To delete all devices connected to the network, press and hold the coordinator button for 15 seconds. The colour of the
button changes from red to amber.
To delete all devices connected to the KL08RF, press and hold the pair button on the KL08RF for 15 seconds. The G1 and G2
LEDs turn from ashing red to solid red then go o. The nal step is to press the Reset button once.
Note: After all devices have been deleted from the wireless network, they will need to be reinstalled. Refer to the instruction
manuals.
Universal Gateway
Connecting the KL08RF (s) to the ZigBee Wireless Network
1. On powering up the KL08RF, actuator LEDs will light up green then go o, then
the Network Status LED ashes green.
2. Remove the coordinator from the KL08, access the SALUS SmartHome App and
add your KL08RF. When in Pairing Mode, the Universal Gateway will start ashing
red. The Network Status LED on the KL08RF goes steady green when connected.
3. Repeat the process for every KL08RF in the system. Note that one Universal
Gateway can support up to 100 devices (thermostats, TRV’s, etc.).
4. To identify your KL08RF (WC) number press Pair for one second. The LED on the
zone number lights green: WC -1=Zone 1, WC-3=Zone 1, 2, 3, and so on. The
Network Status LED is used to identify WC-9.
5. To pair your SALUS thermostats, see your thermostat manual.
6. The Universal Gateway will turn solid blue automatically, once the pairing process is complete.
Note: To restore the KL08RF back to factory default settings at any time, press and hold the pair button on the KL08RF for 15
seconds. The G1 and G2 LEDs turn from ashing red to solid red then go o. After that please press the Reset button once.
Checking the System Conguration and Communication
Go to the SALUS SmartHome App and press the Identify button. The device will start ashing. Stop the identify process by
pressing the button from the App again.
Press and hold the Pair button on the WC for ve seconds. All devices connected to the KL08RF will ash. To stop checking,
press and hold the Pair button again for ve seconds.
Deleting all Devices from the Wireless Network
You can remove your devices from the SALUS SmartHome App, Equipment, All equipment menu.
To delete all devices connected to the KL08RF, press and hold the pair button on the KL08RF for 15 seconds. The G1 and G2
LEDs turn from ashing red to solid red then go o. The nal step is to press the Reset button once.
Note: After all devices have been deleted from the wireless network, they will need to be reinstalled. Refer to the instruction
manuals.
0
0
Old version New version
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Salus KL08RF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Salus KL08RF in the language / languages: English as an attachment in your email.

The manual is 5,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info