NSB Mode depends on the NSB wired connection.
0V=NSB OFF
230V=NSB ON
This function will be activated only when the device is running in Auto Mode.
If the thermostat receives a NSB signal then it will switch to - . If the NSB is turned
off, the unit will function in and . Y ou can manually set the thermostat on NSB
by moving the box on the icon.
4. Button F unctions
Mode selection.
Long press to r eturn home without saving.
OK key. Short press to confirm selection.
Long press to sav e and return home.
Long press to enter T emperature offset Heat/Cool.
Decrease or increase Setpoint T emperature.
In Auto Mode by tapping
the or key you
can view the Setpoint
T emperature.
In Auto Mode by holding
the or key you will
access Manual Override
Mode.
After selecting the
temperature press
and the will appear.
Note: In Auto Mode the change in Manual Override Mode is temporar y. This is
indicated by the icon. When used as a stand alone, the change is permanent.
In Sunny/ Moon/ Frost
Mode by tapping the
or key you will access
Manual Override Mode.
In Sunny/ Moon/ Frost
Mode the change will be
permanent.
When Auto Mode is
selected again the
permanent override
will end.
5. F rostschutz
Move the box by tapping
or on the Frost
Mode Indicator The device
will enter in Frost Mode.
In Frost Mode you can
select a temperature
between 5°-17°C.
Press the or key to
set the temperature.
Note: During the set-up, pr ess at any time to return to the previous scr een or
long press to return to Home display .
Pr oduct Compliance & Safety Information
Product Compliance
SALUS C ontrols hereby declares that the pr oduct complies with the essential
requirements of the follo wing EC Directives: 2014/30/EU, 2014/35/EU and
2011/65/EU. The full text of the EU Declaration of Conformity is available at the
following internet address: www .saluslegal.com.
Safety Information
Use in compliance with safety regulations. The unit is to be used for the contr ol of room
temperature inside the house.
Installation
This accessory must be fitted by a competent person, and installation must comply with
the guidance, standards and regulations applicable to the city , country or state where the
product is installed. F ailure to comply with the relevant standar ds could lead to prosecution.
Note: All electrical installation work should be car ried out by
a suitable qualified electrician or other competent person.
Product Description
Thank you for purchasing the SAL US HTRS230 Thermostat. This thermostat is a
device that lets you customise the heating and cooling of your home as needed.
The HTRS230 device from SAL US Controls is a stylish and accurate digital room
thermostat that is fitted with a large easy to read L CD screen and one touch
buttons. Y ou can now simply adjust your home temperatur e as desired in order
to create a comfortable home environment.
W e hope you enjoy our product.
Contents of the box
Manual Contents:
Box Contents
Introduction
Product Compliance and
Safety Information
Installation
User Interface
Status/LED indication
Installers notes
Warranty
Icons used in this manual:
Safety
Important info
Y our benefit
Fixing Screws
1 x Installer Manual
Digital Thermostat
Model: HTRS230
INSTALLER M ANUAL
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.
Sales: T: +44 (0) 1226 323961
E: sales@salus-tech.com
Technical: T: +44 (0) 1226 323961
E: tech@salus-tech.com
www.salus-controls.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls
plc reserve the right to change specification, design and materials of
products listed in this brochure without prior notice.
Issue Date: Dec 2015
00086/2
For PDF Installation guide please
go to www.salus-manuals.com
Warranty
SALUS Controls warrants that this product (HTRS230) will be free from any
defect in materials or workmanship, and shall perform in accordance with
its specification, for a period of five years from the date of installation. SALUS
Controls sole liability for breach of this warranty will be (at its option) to repair
or replace the defective product.
Customer Name: ......................................................................................................................................
Customer Address: .................................................................................................................................
.............................................................................................................................................................................
....................................................................................... Post Code: ............................................................
Tel No: ................................................................ Email: .............................................................................
Engineers Company: .............................................................................................................................
Tel No: ................................................................ Email: .............................................................................
Instalation Date: .......................................................................................................................................
Engineers Name: ......................................................................................................................................
Engineers Signature: .............................................................................................................................
8. Setting the Thermostat
Device
No
Function Values Denition Default
Value
d01 Heating control 0 PWM 0
1 On-Off: 0.5°C(± 0.25°C)
2 On-Off: 1.0°C(± 0.5°C)
d02 Room temp offset -3.0°C to
+3.0°C
Offset room temp measuring
error(in 0.5°C)
0.0°C
d05 Cooling control 1 On-Off: 0.5°C(± 0.25°C) 2
2 On-Off: 1.0°C(± 0.5°C)
d07 Valve protection 0 Disable 1
1 Enable
d08 Frost Setpoint 5.0-17.0°C 5.0°C
d12 Max. heating setpoint 5.0-35.0°C 35.0°C
d13 Min. cooling setpoint 5.0-40.0°C 5.0°C
d18 Heating/Cooling
Mode
0 No connection 0
1 Connection
d19 Cooling Blocked 0 Cooling allowed 0
1 Cooling disabled
11. Factory Reset 14. Technical Specification
12. Heating/Cooling Mode
13. Temperature Offset (TemperatureCalibration)
Press the indicated keys
together for 3 seconds.
Long press in order to
enter in Settings Mode.
Press to confirm
Press to confirm
Select P47 if you want to
reset to factory settings.
Press to confirm
Note: In order to
quickly reach 47 you
can hold down
key. The display will
fast forward to step 5.
9. Setting the Thermostat
Note: The d20 will help you to reduce the power outlet on
the thermostat.
Setting the hysteresis
You can set the hysteresis by entering in Installer Mode, accessing d01 and after
that selecting the desired value ( PWM / 0.5°C / 1.0°C ).
Heating and Cooling Selection
Manually
The mode will be indicated by the flashing icons
Press or to change the modes.
Auto
The CO terminal needs to be connected.
After that the heating and cooling functions will be done automatically.
In Installer Mode, d19 has to be set on 0.
10. Setting the Thermostat
Cooling blocked
When the thermostat is set on Cooling Disabled (d19-->1) it will block the
cooling function for single rooms until the device will receive the heating
command. During the periods of Cooling Blocked no special indicator will be
displayed on the LCD screen. Cooling mode indicator will also be turned off.
Protection
When room temperature is over the limit of 36°C, all heating outputs will be
turned off regardless of the control pattern and delay timers. When room
temperature is under the limit of 4°C, all cooling outputs will be turned off
regardless of the control pattern and delay timers.
Heating Mode Cooling Mode
Temperature Mode Heating Cooling
Sunny 20.0ºC 20.0ºC
Moon 17.0ºC 26.0ºC
Frost (heat system)
5ºC -
The Temperature Offset can be set at any value between
-3°C and +3°C. Press OK to confirm.
Model: HTRS230
Operating Voltage: 230VAC / 50Hz
Max Switching Current: 0,5A
Max No. Actuators: 5pc
Hysteresis: 0,5C /1C
Size: 85mm / 85mm / 25mm
Humidity: 60ºC, 85% RH
Temp Range: 5ºC - 40ºC
Storage Temp: -25ºC - 60ºC
Safety Class: IP30
Certification: CE, ROHS II
HRTS230 Thermostat
Gently remove front housing and make the
wiring connections.
2. T erminal Connection
N
N
L
CO
L
ACTUAT OR
E.G.
HEAT
PUMP
EXTERNAL
CLOCK
230VAC
50Hz
1. Mounting the Thermostat
N
CO
L
Note: Y ou can wire the thermostat directly to the
KL04NSB, KL08NSB wiring centre or to an actuator
(purchased separatly).
3. Thermostat Icons
BOX means to select mode.
e.g. means Hi temp is selected
means the Hi temp is not selected.
Sunny: Hi comfor table temperature
Moon: Low comfortable temperature
Indicates AUTO ON or A UTO OFF
Frost P rotection Indicator:
Frost pr otection is active, not available in cooling mode.
Heat Mode indicator: Indicates heating is running
Cood Mode indicator:
The icon is flashing when cooling mode active
T emperature indicator
• Display the room temperature
• Display the set temp
T emporary override indicator: I f the set temperature is changed
when in program mode, the hand will appear until the next
programs starting time.
OR
Y ou can change the Modes by tapping or and position the box on
the desired one.
Note: The NSB function will be available only when you also have another device
that can send a NSB signal (HTRP230 thermostat, external clock, NSB switch or
another clock thermostat).
6. Night Setback Function (NSB)
7. Installer Mode
Select P49 if you want to
enter Installer Mode.
Press to confirm.
Y ou have reached the
Installer Mode. Select
your options by using
or and then confirm
by pressing .
Note: This function allows you to
customise your thermostat as you
desire. T o select the device level
use to jump to the next one d1
> d2 > d5. On the desired level press
then you can choose your
preferences b y using or .
Press the indicated keys
together for
3 seconds.
Note: L CD backlight is activated by pressing any key.
W all mounting
For wall mounting , mark the correct
possition on the wall and mount the
rear case to the wall.
Install the HTRS230 digital room thermostat at roughly 1.5m above floor level. It should
be mounted in a location where the thermostat is easily accessible and away from dir ect
sunlight. Y ou can mount the thermostat directly on the wall or you can install it on top of a
wall-box.