INSTALLATION
Please read the important safety information at the start of this manual before you
begin to install the device.
The Frost Thermostat should be located in the coldest part of the building, but where
it can respond to a rise in temperature when the boiler switches on. The ideal position
to locate the FT100 frost thermostat is about 1.5m above floor level, in a location
where the thermostat is accessible, reasonably lit and free from extremes of
temperature and draughts. Do not mount the thermostat on an outside wall, above a
radiator or in a location where it may be subjected to direct sunlight.
The electrical connections to the FT100 are made to the supplied industry standard
backplate. This simplifies installation, as no connections are made to the controller
itself. Connection details are shown below - no Earth connection is required for the
correct and safe operation of the FT100, but a parking terminal is provided to connect
an Earth wire if one is present.
FT100 INSTRUCTION MANUAL
4
Backplate Connections
Terminal Description Backplate
N Mains Neutral
L Mains Live
SL Switched Live
(Normally Open Contact)
Earth Parking (no electrical
connection)
After installing the backplate in a suitable location, wiring connections can be made
as shown above. The following criteria apply to the installation:
The incoming AC mains supply should be 230V AC and fused at 5 amps.
Optimum cable size for installation is 1.5 mm2; wiring colours should be in
accordance with the current requirements of the IEE Wiring Regulations.
Cable entry should be from the rear of the backplate.
All wiring connections should be securely made, and be firmly gripped
beneath the square brass washer on each terminal.
Salus FT100 Manual 001:89 29/11/10 22:57 Page 4
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Salus FT100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Salus FT100 in the language / languages: English as an attachment in your email.

The manual is 3,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info