6.3 Chimney and flue pipes
The flue pipe’s dimensions and quality must comply with the local applicable regulations prior to connecting
the stove to the flue pipe. Therefore the dimensions must be calculated properly.
We guarantee the proper functioning of the appliance if the chimney draught is at least 12 Pa. If the
chimney draught is too high, then a damper must be incorporated.
If there isn’t enough chimney draught, then the following measures can be considered:
Extending the chimney
Improving the insulation of the chimney (less cooling of the flue gases)
Increasing the supply of combustion air into the space in which the appliance is installed.
Improving the airtightness of the chimney
The nearer you place the retardant plate, the easier you may control the chimney draught. If this doesn’t
help, installing a flue gas flap in the drain pipe may also be the solution.
Many problems with inset fires are caused by badly working chimneys. Therefore some suggestions:
A round channel is preferred (minimum friction)
The diameter of the chimney may not be smaller at any point than that of the appliance
The mouth of the chimney should be unobstructed
The chimney should be as close as possible to vertical with as few curves as possible. Carrying is
possible only when the angles are up to 45 degrees.
The chimney must not draw in extra air. Watch out for flue dampers and cleaning hatches in the cellar
or on the roof!
The chimney may not have too many connections - that reduces the upwards pressure. Consult your
chimney specialist!
Flue connections to different stoves and fireplaces may not be located opposite each other at the same
height, in order to prevent the chance that combustion gases will not be drawn out. Two flue
connections must be at separated vertically by at least 30 cm.
For details on chimneys we refer you to the relevant regulations with which the chimney needs to comply.
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Saey QUBE 8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Saey QUBE 8 in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 1.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Saey QUBE 8

Saey QUBE 8 Usermanual and installation guide - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info