TEST RUN
Start the tool and check that the drill bit does not rotate off-centre.
Otherwise, switch-off the tool immediately and eliminate the
cause.
USABLE WORKING TOOLS
Drill bits available on the market.
Drills with reduced diameter shafts can only be used when
drilling wood at high speed and within the limits specified in
the technical data.
MAINTENANCE
All maintenance operations are carried out with the power supply
disconnected.
At the end of each work session, or when required, remove any
dust from the body of the tool using a jet of compressed air,
paying particular attention to the motor ventilation slots.
No other maintenance operations must be undertaken by the
user.
Maintenance and cleaning of the inner parts, like brushes, ball
bearings, gears etc. or others, must be carried out only by an
authorized customer-service workshop.
ELECTRIC SAFETY - LOW TENSION
The tests have been carried out in accordance with the standard:
EN 60745-1 safety of hand-held electric motor operated tools
EN 60745-2-1 particular requirements for
drills.
RADIO SUPPRESSION
The tools are suppressed in accordance for the prevention and
elimination of radio disturbances measured in accordance with
standard: EN55014-1+EN55014-2; EN61000-3-2+EN61000-3-3.
NOISE
The noise level produced is:
84 dB (A) for TR102 -TR10
85 dB (A) for TV10
measured according to regulation EN ISO 3744 + UNI EN ISO
11203.
Warning: wear suitable hearing protections! (see warnings).
MEAN ACCELERATION VALUE
The mean quadratic acceleration value is less than 2,5 m/sec
2
measured in accordance with standard UNI EN 28662 + UNI EN
ISO 5349.
GUARANTEE
All tools manufactured by RUPES Spa are guaranteed for 12
months from the date of purchase against fabrication and material
defects.
All tools must be used only with RUPES original accessories and
spare parts: we refuse all responsibility for damages or accidents
caused by non-observance of this rule which will also cause the
termination of the guarantee.
The guarantee will no longer be valid if the instructions contained in
this booklet are not followed, if the tool is used for purposes other
than that for which it is intended, if it is dismantled, interfered with in
any way or damaged due to neglect.
The guarantee will be made valid by filling-in the form on the
inside back cover of this instruction booklet.
If the tool is found to be defective or malfunctions, it should be retur-
ned carriage free in one piece in its original packing together with
the guarantee certificate to the manufacturer or to one of the Assi-
stance Centres listed in the appendix to this booklet.
The guarantee does not automatically imply replacement of the tool.
RUPES Spa reserves the right to make any technical or design
modification to its products without prior notice.
The manufacturer is not liable for any print errors. This document
voids and replaces previous ones.