489871
8
Zoom out
Zoom in
Previous page
1/108
Next page
English - 8 -
When observing the safety rules and using the original accessories, this hot air tool is intended for all appli-
cations with hot air that are listed in these operating instruction
A falling down nozzle can set an object on fire. Nozzles must be mounted firmly and secure on the
unit.
Touching a hot nozzle can lead to serious burns. Before attaching or replacing a nozzle, allow the
unit to cool down completely or use a suitable tool.
A hot nozzle can set a surface on fire. Place down hot nozzles only on fire-proof surfaces.
An incorrect or defective nozzle can lead to heat accumulation and damage the unit. Use only origi-
nal nozzles according to the table that are suitable for your unit.
Technical Data
A B C
Voltage [V] 230 120 100 230 120 100 230 120 100
Frequency [Hz] 50/60 50/60 50/60
Power [W] 1600 1200 1100 1800 1400 1200 2000 1500 1300
Current con-
sumption
[A]
710118121291313
Switch positions 0 - l - ll 0 - l - ll 0 - l
Position I II I II I II Manually adjustable Electronically adjustable and controlled
Temperature [°C] 350 500 500 500 100–550 80–550 80–550 80–650 80–650 80–650
[°F] 660 930 930 930 2101020 180–1020 1801020 180–1200 1801200 180–1200
Position I II I II I II I II I II I II Electronically adjustable
Air flow [l/min] 350 500 250 400 250 400 250 550 250 450 250 450 200–550 200–500 200–500
[cfm] 12.5 17.5 8.8 14 8.8 14 8.8 19.5 8.8 16 8.8 16 7–19.5 717.5 7–17.5
Weight
with cord
[kg] 0.68 0.74 0.74 0.72 0.78 0.78 0.78 0.84 0.84
[lbs] 1.5 1.63 1.63 1.6 1.72 1.72 1.72 1.85 1.85
Dimensions
L x B x H
[mm] 230 x 80 x 240
[inch] 9.1 x 3.2 x 9.5
Protection class II/ (Double insulated)
Intended Use
Applications A B C
Shrinking of shrinkdown tubing, solder connectors and solder terminals, packaging and electrical
components.
●●●
Deforming of articles made from acrylic, PVC, and polystyrene, tubing, plates and profiles, as well as
moist woods.
●●●
Welding of thermoplastic polymer, flooring materials of PVC and linoleum, PVC-coated fabric, tar-
paulins and foils.
●●
Soldering of tin, special silver solder, SMD elements, cable lugs, and for loosening soldered connec-
tions.
●●
Paint removal - Removal of old and even thick coatings of oil paint, varnish and synthetic plaster. ●●●
Drying of colour shade samples, filler, adhesives, construction joints and stucco forms. ●●●
Joining adhesives – Large-surface gluing with contact adhesives, activation of pressure-sensitive
adhesives, acceleration of bonding processes, releasing of bonding points as well as releasing or
bonding of edge band or venee.
●●●
Defrosting of icy stairs and steps, door locks, trunk lids, car doors or water pipes, as well as for
defrosting refrigerators and ice boxes.
●●●
Disinfection – With hot air of 600 °C, you can quickly rid animal sties/stables of bacteria. Wood-
worm infestation can be controlled (Caution: Danger of fire! Do not heat up the wooden surface exces-
sively).
●●
Attaching the Nozzle onto the Heating-element Tube 3
A
●●●
B
●●●●
C
●●●●●●●
WELDY.book Seite 8 Mittwoch, 17. Mai 2006 1:02 13
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rupes GTV20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rupes GTV20 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 3,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info