Installation Instructions
This section describes how to set up your re.
BEFORE YOU START
1. Ensure that all packing items are removed (read any warning labels carefully) and retain all packing for possible
future use e.g. in the event of moving house or returning the appliance to your supplier.
2. Before connecting to the mains supply, check that the supply voltage is the same as that stated on the appliance.
INSTALLATION
Place the appliance against a wall.
Connecting the Transducer Unit + Lamps
1. Release the two red tabs by turning them by 90 degrees (see Fig 2)
2. Lift out the Sump Nozzle (Fig 3)
3. Insert lamps into lamp holders (Fig 4), carefully locating the pins into the holes (Fig 4a)
4. Push lamps rmly into place
5. Place the Transducer Unit into the sump and join the cable to the connector on the sump (Fig 5)
6. To ensure that the Transducer Unit is correctly placed in the sump, the tab on the Transducer Unit should be lined
up with the moulded recess in the sump (Fig 5a).
7. Ensure that the cable is not placed above the disc on the Transducer Unit (Fig 5b). To prevent the cable becoming
pinched between the nozzle and the sump, place the cable in the slot in the wall of the sump.
8. Replace the Sump Nozzle and secure it by turning the two red tabs by 90 degrees (Fig 6)
Filling the Water Tank
9. Place Water Tank in sink and remove cap (turn anti-clockwise to open) (Fig 7)
10. Fill Water Tank with ltered tap water only. This is necessary to prolong the life of the ame and smoke effect
producing unit. The water should be ltered through a conventional domestic water lter unit and the lter should be
replaced regularly. Distilled water must not be used.
11. Screw the cap back on – do not overtighten.
12. Place the Water Tank in the Sump, with the tank cap facing down and the at side of the tank facing outward (Fig 8)
Assembling the re
13. Place the Fuelbed on top of the Water Tank and Mist Nozzle (Fig 9)
Connect the power cable to the appropriate power connector at the back of the appliance and
Plug the power cable into a 13amp/240volt outlet. The appliance is now ready for use.
Operating the Fire
This section describes how to activate your re using either the manual controls or remote control.
MANUAL CONTROLS
The manual controls are located beneath the hinged ap.
(See Fig.10 for Manual Control lay out)
Switch ‘A’:- Controls the electricity supply to the Fire.
Note: This switch must be in the ‘ON’ ( I ) position for the Fire to operate.
Switch ‘B’:- Press once to turn on the ame effect. This will be indicated by an audible beep. Although the main
lights operate immediately it will take a further 30 seconds before the ame effect starts.
Press to put re in to standby mode. This will be indicated by one beep.
Control Knob ‘C’:- Controls the intensity of the ame effect.
Turning the control knob to the left increases the ame effect, turning the control knob to the right will
decrease the ame effect.
GETTING THE DESIRED FLAME EFFECT
1. The ame control knob ‘C’ (Fig.10) may be turned up or down to give a more realistic effect.
2. Generally the ames appear more realistic when the ame control is turned down.
3. Give the ame generator time to react to changes you may make.
4. The appliance will use less water if the ame effect is set to a lower level (control knob ‘C’).
5. Do not tilt or move the appliance while there is water in the tank or sump.
6. Make sure that the appliance is on a level oor.
2
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ruby Fires RF40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ruby Fires RF40 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info