Troubleshooting
Symptom Cause Corrective Action
The  ame e ect will
not start.
Mains plug is not plugged in.
Low water level.
Low voltage connector not connected properly.
(See Fig.6)
The Transducer Unit is not sitting correctly in
the sump
Check plug is connected to wall socket correctly.
Check that the water tank is full and there is
water in the sump.
Check that the connector is inserted correctly.
(See Fig.6)
Ensure the Transducer in sitting down into the
moulded recess in the sump
The  ame e ect is too
low.
Flame e ect control knob is set too low.
(See Fig.2)
The Metal Disc in the transducer might be dirty
(See Fig.12)
The wire from the Transducer Unit is sitting over
the metal disc
Increase level of  ame by turning Control knob
‘D’ anti clockwise slowly. (See Fig.2)
Clean the Metal Disc with soft brush supplied.
(See Fig.12) See ‘Maintenance. for a step by step
procedure.
Direct the wire to the back of the sump and
make sure it sits into the side slot exiting the
sump.
Unpleasant smell when
unit is used.
Dirty or stale water.
Using un ltered tap water.
Clean the unit as described under maintenance.
Use only  ltered tap water.
The  ame e ect has
too much smoke.
Flame e ect setting is too high. Turn the  ame e ect Control knob C clockwise,
about ¼ a turn, at a time. Give the  ame
generator some time to adjust to the new
setting. (See Fig.2)
Main lamps are not
working and there are
no  ames or smoke.
There is no water in the water tank Follow instructions under
Maintenance, ‘Filling the water tank’.
Check the plug is connected to the wall socket
correctly and that Switch A Fig. 2 is in the
‘ON’ ( I ) position.
10
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ruby Fires RF30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ruby Fires RF30 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info