GB
4.4 Troubleshooting
Fault Possible cause(s) Remedy
Tab. 3: Error diagnosis
Appliance does not
start.
The switch switches off
during operation.
The appliance is not
switched on.
The room temperature is
above the temperature set at
the thermostat.
The thermal overload switch
has triggered. The appliance
has exceeded the maximum
permissible temperature.
The room temperature is
above the temperature set at
the thermostat.
The thermal fuse has trig-
gered
Turn the heating level switch to
position "I" or "II".
Increase the thermostat tem-
perature.
Switch off the appliance by
moving the heating level switch
to position "0" and pull the
plug out of the socket. Allow
the appliance to cool down for
several minutes. Check the air
inlet and air outlet openings
and remedy the cause of the
overheating before restarting
the appliance.
Increase the thermostat tem-
perature.
Please contact the ROWI
Service-Team (Chapter 5)
Appliance does not
start.
No power or voltage too
low.
Make sure that the connector is
plugged into the socket. Check
the power supply voltage.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rowi HHL 2000 3-4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rowi HHL 2000 3-4 in the language / languages: English, German as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info