762630
14
Zoom out
Zoom in
Previous page
1/71
Next page
9
power cord.
Do not move the vacuum cleaner by pulling on the power
cord, the appliance must be moved using its carrying
handle.
Do not use the power cord or the hose to lift the appliance.
Switch off and unplug your vacuum cleaner after each use.
Always switch off and unplug your vacuum cleaner before
maintenance or cleaning.
Your vacuum cleaner is fitted with a safety appliance which
prevents the motor from overheating. In certain cases (when
used on chairs, sofas, etc.) the safety appliance may be
tripped and the appliance may make an unusual noise that
is not serious. Only use original Rowenta accessories and
filters.
Check that all the filters are in place.
Do not operate your vacuum cleaner without the filtration
system fitted (foam, microfilter and filter).
Never place the foam and microfilter in the appliance unless
they are completely dry.
If you have any difficulties in finding accessories or filters for
this vacuum cleaner, contact the Rowenta Customer
Service.
USING FOR THE FIRST TIME
1• Fitting the elements onto the
appliance
Clip the end of the hose to the suction inlet located at the
front of the appliance (fig.1). To remove, unclip the end
using the clip and remove.
Fix the accessory holder* (I-II.26) to the notch in the self-
standing position (7) located at the back of the vacuum
cleaner and store the accessories on top (fig.2).
If you have the ERGO COMFORT chain of accessories
without the tube/nozzle Locking system (I)*
- Fit the telescopic metal tube to the end of the nozzle until
you hear a 'click' (Fig 3) (To remove, press the tube lock
button and pull).
- Fit the nozzle for all floor types* (I.20) to the end of the
telescopic metal tube (Fig.4a).
- Adjust the telescopic metal tube to the desired length
using the telescopic system (Fig 4b).
If you have the ERGO COMFORT chain of accessories
with the tube/nozzle Locking system (II)*
- Fit the telescopic metal tube to the end of the nozzle until
you hear a 'click' (Fig 3) (To remove, press the tube lock
button and pull).
- Fit the nozzle for all floor types* (II.20) to the end of the
telescopic metal tube until you hear a 'click' (Fig.5a) (To
remove, press the tube lock button and pull).
- Adjust the telescopic metal tube to the desired length
using the telescopic system (Fig 5b).
Fit the corresponding accessory to the end of the metal
telescopic tube or the nozzle:
- For rugs and carpets: use the multi-surface nozzle in the
retracted brush position or the Turbobrush* (fibres and
animal hairs).
- For smooth floors with joins (tiled floors) : use the 2-
position nozzle (I-20* II-20*, depending on the model) on the
smooth floor setting (extended brush position), or, for a
better result, use the nozzle for smooth floors with joins
without the removable brush (I-27a* II-27a*, depending on
the model).
- For smooth floors, including delicate smooth floors
(parquet flooring), use the 2-position nozzle setting (I-20* II-
20*, depending on the model) on the smooth floor setting
(extended brush position), or, for a better result, use the
nozzle for smooth floors with the removable brush (I-27b* II-
27b* depending on the model).
- For corners and hard-to-reach areas: use the telescopic
crevice nozzle*.
- For furniture and fragile surfaces: use the integrated
nozzle brush (EASY BRUSH) or the upholstery nozzle*.
2 Plugging in the power cord and
switching on the appliance
Unwind the power cord completely, plug in your vacuum
cleaner and press the ON/OFF button (fig. 8).
USE
IMPORTANT! If the accessory holder* is positioned
behind the appliance, it is essential to remove the
accessories in order to open the vacuum cover.
IMPORTANT: Always switch off and unplug your
vacuum cleaner before changing the accessories.
ERGONOMIC RECOMMENDATIONS
Ergonomic, the ERGO COMFORT range has been
designed to facilitate and improve user comfort
when vacuuming.
To prevent bending over and to ensure upright
posture, make sure to:
1. Adjust the length of the ERGO COMFORT
telescopic metal tube to your body size (fig.6).
2. Place your second hand in front of the ERGO
COMFORT nozzle handle (fig.7).
*According to model: these parts are specific to certain models
or they are accessories that can be purchased separately.
IMPORTANT : The nozzle for smooth floors with joins
(I-27a* II-27a*) is used to measure the performance
related to the energy label.
The nozzle allows your appliance to achieve optimum
dust removal performance on smooth floors with joins.
IMPORTANT: do not operate your vacuum cleaner
without the filtration system fitted (foam, microfilter and
filter).
EN
RO_ASPIRATEUR_EFC_765275-01_765275_01 11/07/14 14:24 Page9
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rowenta RO6723 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rowenta RO6723 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Turkish, Spanish as an attachment in your email.

The manual is 2,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info