762412
23
Zoom out
Zoom in
Previous page
1/118
Next page
* According to model: this is either equipment specific to certain models or available as an optional accessory
• Open the lid (8) of your vacuum cleaner fig. 13.
• Pull out the HEPA* filter cassette (13) - fig. 31-32.
• Tap the HEPA* filter cassette (13) on the top of a bin - fig. 33.
• Then pass it through clear water, fig 34 and let it dry for at least 24 hours- fig 35.
• Ensure that the HEPA* filter cassette (13) is fully dry before re-inserting it in the machine.
• Place the pins in the notches- fig. 36.
• Adjust the HEPA* filter cassette (13) in its compartment - fig. 37.
• Make sure the HEPA* filter cassette (13) is properly positioned before closing the lid. (8).
CHANGING THE HEPA FILTER CASSETTE * (Ref. RS-RT9926)
• Open the lid (8) of your vacuum cleaner fig. 13..
• Pull out the HEPA* filter cassette (13) - fig. 38-39.
• Put the cassette in the bin- fig.40.
• Place the pins of the new HEPA* filter cassette in the notches - fig 41.
• Adjust the new HEPA* filter cassette (13) in its compartment - fig. 42.
• Make sure the HEPA* filter cassette (13) is properly positioned before closing the lid. (8).
CLEANING THE VACUUM CLEANER
• Wipe the body of the appliance and the accessories with a soft damp cloth, then dry.
• Wipe the lid with a dry cloth -fig. 43.
• Do not use aggressive or abrasive detergents.
6. TROUBLESHOOTING
Important : As soon as your vacuum cleaner begins to work less well than usual, switch it off by pressing
on the On/off pedal, before doing any checking.
YOUR VACUUM CLEANER DOES NOT START
• The appliance is not connected to a power supply . Check that the appliance is correctly connected.
IF YOUR VACUUM CLEANER HAS NO SUCTION
• An accessory or the flexible tube is blocked : unblock the accessory or the flexible tube.
• The lid is not properly closed : Check the positioning of the bag and close the lid again.
IF YOUR VACUUM CLEANER LOSES SUCTION, MAKES NOISE, WHISTLES
• An accessory or the flexible tube is partially blocked. Unblock the accessory or the flexible tube.
• The bag is full, or saturated with fine dust : replace the paper bag (16a), or empty the textile bag* (16b).
• The “bag full” indicator is red : the filtration system is saturated.
- HEPA* Cassette : change the HEPA* cassette (13) and replace it in position, or wash the HEPA* cassette
(13) according to the procedure.
- Micro filter* : take out the micro filter* and replace it with a new one (ref. ZR0039 01).
• The mechanical power control is open : close the mechanical power control.
IF THE “BAG FULL” INDICATOR STAYS RED
• The bag is full. Replace the paper bag, (16a) or empty the textile bag* (16b).
IF THE LID DOES NOT CLOSE (filter presence detector 13bis activated)
• Check that you have installed a HEPA* filter cassette (13) or motor protection grill (11) and check that it
is correctly positioned.
IF THE SUCTION NOZZLE IS DIFFICULT TO MOVE
• Open the regulator to turn down the power.
IF THE CABLE DOES NOT COMPLETELY RETRACT
• The cable is held back by something outside its entry point : straighten out the cable and press on the
cable return pedal.
EN
902455B_mini-space_902455B 07/10/10 11:08 Page14
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rowenta RO1845 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rowenta RO1845 in the language / languages: English, Dutch, French, Portuguese, Spanish as an attachment in your email.

The manual is 6,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info