POWER
• Before using for the first time, check to make sure that your power supply system corresponds to that indicated on the appliance.
• Your appliance may be operated on an outlet without a grounding contact. This is a class II appliance (double electrical insulation).
PRODUCT ASSEMBLY
• To preserve their quality, the filters are protected in packaging and installed on the appliance.
• Do not use the appliance without first having removed the filters from their packaging.
- Open the front panel of the appliance (fig. 1).
- Take the filters out of the appliance and remove their packaging.
- Put the filters back into the appliance (following the order given in fig. 2).
- Close the front panel (fig. 3).
- Insert the hooks into the notches on the base.
- Press on the cover to fasten solidly in place.
IONIC SYSTEM
• The negative ions that are effectively expelled by your appliance provide balance to the air in the room, pro-
ducing the kind of wellbeing that you feel in the mountains or at the seaside, where negative ions are naturally
found in very large quantities.
OPERATION
• Before starting up the appliance, make sure that:
- the appliance is positioned as indicated in this guide,
- the air inlet and outlet grilles are totally free of obstruction.
• The purifier may be activated by pressing the buttons on the control panel or the remote control. The purifier
emits a beep with every action on the control panel or the remote control.
Button B: Start and Select Speed
Press button B to start up the appliance and select the desired speed by pressing repeatedly (indicator light C
indicates the speed selected).
Button D: Programming automatic appliance shutoff
• You have 4 choices: 1, 2, 4 or 8 hours of operation.
• Press once on button D, the one-hour timer is activated, the 1h indicator light lights up.
• Press a second time on button D, the two-hour timer is activated, the 2h indicator light lights up.
• Press a third time on button D, the four-hour timer is activated, the 4h indicator light lights up.
• Press a fourth time on button D, the eight-hour timer is activated, the 8h indicator light lights up.
• To stop the timer function, press once more on button D.
Button F: Ioniser functions
• Press once on button F; the Ioniser is in operation and the indicator light lights up.
• To stop the ionizer, press once more on button F.
Button A: Appliance shutoff
• Press on button A to switch the appliance off.
Using the remote control unit
The buttons on the remote control unit are identical to those on the appliance’s control panel. The information is transmitted to your appliance by an infrared
signal from an infrared light-emitting diode located on the front side of the remote control unit. The infrared receiver is located on the purifier’s control panel.
Do not scratch the infrared light-emitting diode or the infrared receiver on your purifier.
To use the remote control unit, point the infrared light-emitting diode toward the purifier and press the desired button.
Make sure that there are no obstacles between the infrared light-emitting diode and the receiver.
The maximum range is approximately 6 metres, facing the purifier.
Remote control unit power supply: The remote control unit operates on one CR2032 button battery, supplied.
Do not touch the battery with your fingers
Place the battery in its housing following the polarity indicated in its housing.
MAINTENANCE
• You must switch off your appliance by pressing button A and unplug it before undertaking any maintenance operations.
• It can be cleaned using a slightly damp cloth.
• Important: Never use abrasive products which could harm your appliance’s appearance.
CHANGING THE FILTERS
• Spare filters are available in shops under the product reference number: XD6010F0 (1 HEPA filter + 2 activated charcoal filters).
• The average useful lifetime of the filters is 6 months for the HEPA filter and 3 months for the activated charcoal filter, under normal conditions of use.
• The HEPA filter must be replaced when it reaches the colour of the indicator (10), even if it has been used for less than 6 months.
• You should clean the prefilter regularly (at least once every 2 to 3 months). Dry carefully before reinstalling.
• IMPORTANT: Do not wash the HEPA filter or the activated charcoal filter.
STORAGE
• When not in use, the appliance should be stored in a dry place.
PROTECTING THE ENVIRONMENT
Your appliance contains many materials that can be reused or recycled. Take it to a collection point or, if there is
none near you, to an authorized service centre for appropriate disposal.
This appliance uses a battery. To protect the environment, do not throw away dead batteries, ins-
tead, take them to a battery collection point. Do not dispose of with household waste.
3
1
2
4
5
Fig. 3
Fig. 2
Fig. 1
GB
If you have any problems or queries please call our
Customer Relations Team for expert help and advice:
HELPLINE:
0845 602 1454 - UK
(01) 4751947 - Ireland
Or consult our web site: www.rowenta.co.uk
(if this is a Rowenta product).
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rowenta PU2010 Vitality at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rowenta PU2010 Vitality in the language / languages: English, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 3,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info