METHOD OF FITTING AND CONNECTING THE APPLIANCE
Before fitting or removing the appliance, ensure that the circuit supplying the appliance is properly switched off.
In accordance with the installation regulations, the supply circuit must be broken on both sides.
This circuit breaker must have a minimum contact gap of 3 mm.
To fix your radiator correctly, you must use screws and plugs appropriate to the type of wall on which it is to be fixed.
- Remove the front cover of the control unit (B, fig. 3) by removing the 2 screws (No. 2, fig. 3).
- Offer the radiator up to the wall, taking account of all the requirements and recommendations above.
- Mark and drill the 3 fixing holes (No. 3, fig. 5).
- Feed the supply cable into the control unit along the cable entry (No. 4, figs. 5 and 6).
- Fix the appliance to the wall, ensuring that the radiant part is horizontal (A, fig. 2).
- Unscrew the two cable clamp screws (No. 5, fig. 5) to free the bridge piece.
- Connect the neutral (blue wire) to the terminal marked N (No. 6N, fig. 5) and the live (brown wire) to the terminal marked L
(No. 6L, fig. 5)
- Refit the cable clamp bridge (No. 5, fig. 5) and tighten the two screws so that the cable is firmly gripped.
- Position the selection pull-cord (No. 7, fig. 3) correctly using one of the two possibilities available (No. 7a or 7b, fig. 5).
(The choice 7b requires the use of the accessory C: see fig. 4 for installation.)
- Refit the front cover of the control unit (B, fig. 3), using the 2 screws (No. 2, fig. 3) and fit the screw covers (included in the
accessories packet).
Ensure that the supply cable cannot come into contact with the radiant part (A, fig. 2a) of your radiator.
The angle of the radiant part to the wall (fig. 2b) can be adjusted between 10° and 30°.
This adjustment is not permitted while the appliance is in operation. It is recommended to wait 15 minutes after switching off the
appliance before adjusting the angle and to proceed as follows:
- Remove the 2 screw covers (No. 8, fig. 3).
- Loosen the 2 hinge screws so that the radiant part is free to rotate.
- Hold the radiant part in the desired position and retighten the 2 hinge screws.
OPERATION
The appliance is turned on by means of the pull-cord (No. 7, fig. 3). When turned on there may be a slight vibration, which should
stop after a few seconds.
CLEANING
• It is imperative that you turn off your appliance (selection indicator at 0) and leave it to cool down properly before cleaning.
• It can be cleaned with a damp cloth.
Important: Never use abrasive cleaners, these will damage the surfaces.
IN THE EVENT OF PROBLEMS
Never dismantle your appliance. An incorrectly repaired appliance can be a danger to the user.
Before doing anything to the appliance, ensure that:
- your appliance is turned off (selection indicator at 0),
- your appliance has cooled down,
- the supply circuit to your radiator is off.
Mod. IR2010
- Position 0: Off
- Position 1: 600 W
- Position 2: 1200 W
Mod. IR2020
- Position 0: Off
- Position 1: 750 W
- Position 2: 1500 W
Mod. IR2030
- Position 0: Off
- Position 1: 600 W
- Position 2: 1200 W
- Position 3: 1800 W
GB
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rowenta IR2010 Sunray at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rowenta IR2010 Sunray in the language / languages: English, German, Danish, French, Italian, Polish, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 9,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info