3. Auto Mode
In Auto mode,
mark appears on the display.
Press the START key, the monitor will automatically
inate the cuff slowly to start measurement.
When the measurement is completed, the cuff
will exhaust the pressure inside. Systolic pres-
sure, diastolic pressure and pulse will be shown
simultaneously on the LCD screen. The measurement is then auto-
matically stored into memory zone.
In order to enhance the probability of pulse arrhythmia detection by
the PARR technology, measurement repetitions are recommended.
This monitor will re-inate automatically to approximately 220 mmHg
if the system detects that your body needs more pressure to measure
your blood pressure.
4. Manual Mode
Switch Auto mode to Manual mode by pressing
the
key on the back of the unit.
The default deation rate is 2.5 mmHg/sec.
Press the START key, the monitor will automati-
cally inate the cuff slowly to start measurement.
While the unit starts deating, press the Marker
key to record the onset of Korotkoff sound as the systolic pressure,
and press the Marker key again to record the disappearance of the
Korotkoff sound as diastolic pressure.
Measurement Procedures Measurement Procedures
When the measurement is completed, the cuff will exhaust the pres-
sure inside. Systolic pressure and diastolic pressure will be showed
simultaneously on the LCD screen.
Note: 1. This monitor automatically switches off approximately 5 min-
utes after last key operation.
2. To interrupt the measurement, simply press the START/STOP or
ON/OFF key; the cuff will deate immediately.
3. During the measurement, do not talk or move your arm or
hand muscles.
Korotko sound of
Systolic pressure
Korotko sound of
Diastolic pressure
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rossmax AC1000f at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rossmax AC1000f in the language / languages: English as an attachment in your email.

The manual is 10,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info