647722
100
Zoom out
Zoom in
Previous page
1/169
Next page
100
Examples of Applications Using the XV-2020
Matrix Control
Select the controllers you want to use to control a specific Tone
parameter. Four control sources are assigned to each Patch.
SOURCE 1–4 (MATRIX CONTROL1–4 SOURCE)
Assign one of the following controllers to Control Source 1–4. If you
wish to use a controller that applies to all Patches, or a controller that
cannot be directly specified here, choose SYS-CTRL1–4, and then
choose the controller using the Control Source 1–4 parameters
(SYSTEM CONTROL SOURCE).
MATRIX CONTROL1–4
This select the parameters to be controlled in the Matrix Control 1-4
Source and the Sens settings, as well as the Tone to which they’re
applied. Up to four parameters can be specified for each controller
and controlled simultaneously.
DESTINATION1–4
(MATRIX CONTROL1–4 DESTINATION1–4)
This chooses the parameters to be controlled.
SENS1–4 (MATRIX CONTROL SENS 1–4)
This adjusts the amount of change that occurs in response to
controller movements. Negative (-) values invert the change. For
example, with LFO Depth, the phase is reversed when a negative
Sens value is chosen. With LFO Rate, setting Sens to a negative value
increases the cycle length, slowing down the LFO, while setting it to
positive value shortens the cycle, speeding it up
TONE1–4 (MATRIX CONTROL1–4, TONE CONTROL
SWITCH1–4)
This selects the Tone to be controlled using the two previous
parameter settings. “ON” activates the control of a Tone, “OFF” de-
activates it, and “REV” reverses the (+) or (-) nature of the change
being applied.
Applications for Patches
Syncing the LFO Cycle to the
System Tempo
1. Click [PATCH].
2. Click the for [PATCH NAME] to select the Patch to be
synchronized.
fig.08-01.eps_50
fig.08-02.eps_50
3. Click [DETAIL] for PATCH COMMON, then set [CLOCK
SOURCE] to [SYSTEM].
fig.08-06a.eps_50
fig.08-06b
4. Click [DETAIL] for LFO 1, click [RATE], then set each tone’s
Rate to the note length corresponding to the
synchronization tempo.
fig.08-07
* TONE 1 – TONE 4 are switched with TONE SELECT, at the upper
right of the screen.
OFF (No controller is used.)
CC01–95 (Controller numbers 1–95 (except for 32))
PITCH BEND
AFTERTOUCH
SYS-CTRL1–4 (System Control 1–4)
VELOCITY
KEYFOLLOW
TEMPO
LFO1(2)
PITCH ENV (Pitch Envelope)
TVF ENV (TVF Envelope)
TVA ENV (TVA Envelope)
OFF (No control) ---
PITCH p. 54
CUTOFF (Cutoff Frequency) p. 57
RESONANCE p. 57
LEVEL p. 100
PAN p. 100
DRY LEVEL p. 78
CHORUS SEND (Chorus Send Level) p. 78
REVERB SEND (Reverb Send Level) p. 78
LFO1(2) PITCH DEPTH p. 57
LFO1(2) TVF DEPTH p. 57
LFO1(2) TVA DEPTH p. 57
LFO1(2) PAN DEPTH p. 57
LFO1(2) RATE p. 56
PCH ENV A-TIME (Pitch Envelope Attack Time)
p. 54
PCH ENV D-TIME (Pitch Envelope Decay Time)
PCH ENV R-TIME (Pitch Envelope Release Time)
TVF ENV A-TIME (TVF Envelope Attack Time)
p. 58
TVF ENV D-TIME (TVF Envelope Decay Time)
TVF ENV R-TIME (TVF Envelope Release Time)
TVA ENV A-TIME (TVA Envelope Attack Time)
p. 60
TVA ENV D-TIME (TVA Envelope Decay Time)
TVA ENV R-TIME (TVA Envelope Release Time)
TMT p. 49
FXM DEPTH (Wave FXM Depth) p. 54
MFX CTRL 1–4 (MFX CONTROL 1–4) p. 80
100


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roland XV-2020 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roland XV-2020 in the language / languages: English as an attachment in your email.

The manual is 4,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info