Roland E-09 MIDI Implementation
System Exclusive messages related to mode settings
These messages are used to initialize a device to GS or General MIDI mode, or change the
operating mode. When creating performance data, a “GM1 System On” message should be
inserted at the beginning of a General MIDI 1 score, a “GM2 System On” message at the
beginning of a General MIDI 2 score, and a “GS Reset” message at the beginning of a GS
music data. Each song should contain only one mode message as appropriate for the type of
data. (Do not insert two or more mode setting messages in a single song.) “GM System On”
uses Universal Non-realtime Message format. “GS Reset” uses Roland System Exclusive
format “Data Set 1 (DT1)”.
GM1 System On
“GM1 System On” is a command message that resets the internal settings of the unit to the
General MIDI 1 initial state. After receiving this message, the E-09 will automatically be set
to the proper condition for correctly playing a General MIDI 1 score.
Status
Data byte Status
F0H 7EH, 7FH, 09H, 01H F7H
Byte Explanation
F0H Exclusive status
7EH ID number (Universal Non-realtime Message)
7FH Device ID (Broadcast)
09H Sub ID#1 (General MIDI Message)
01H Sub ID#2 (General MIDI 1 On)
F7H EOX (End Of Exclusive)
* When this message is received, Rx.BANK SELECT will be OFF and Rx.NRPN will be
OFF.
* There must be an interval of at least 50 ms between this message and the next.
GM2 System On
“GM2 System On” is a command message that resets the internal settings of the unit to the
General MIDI 2 initial state. After receiving this message, the E-09 will automatically be set
to the proper condition for correctly playing a General MIDI 2 score.
Status
Data byte Status
F0H 7EH, 7FH, 09H, 03H F7H
Byte Explanation
F0H Exclusive status
7EH ID number (Universal Non-realtime Message)
7FH Device ID (Broadcast)
09H Sub ID#1 (General MIDI Message)
03H Sub ID#2 (General MIDI 2 On)
F7H EOX (End Of Exclusive)
* When this message is received, the E-09 will be able to receive the messages specified by
General MIDI 2, and use the General MIDI 2 sound map.
* There must be an interval of at least 50 ms between this message and the next.
GM System Off
“GM System Off” is a command message that resets the internal state of the E-09 from the
GM state to its native condition.
Status
Data byte Status
F0H 7EH, 7FH, 09H, 02H F7H
Byte Explanation
F0H Exclusive status
7EH ID number (Universal Non-realtime Message)
7FH Device ID (Broadcast)
09H Sub ID#1 (General MIDI Message)
02H Sub ID#2 (General MIDI Off)
F7H EOX (End Of Exclusive)
* When this messages is received, the E-09 will reset to the GS default state.
* There must be an interval of at least 50 ms between this message and the next.
GS Reset
“GS Reset” is a command message that resets the internal settings of the E-09 to the GS
initial state. This message appears at the beginning of GS music data, and a GS device that
receives this message will automatically be set to the proper state to correctly play back GS
music data.
Status
Data byte Status
F0H 41H, dev, 42H, 12H, 40H, 00H, 7FH, 00H, 41H F7H
Byte
Explanation
F0H Exclusive status
41H ID number (Roland)
dev Device ID (dev: 00H - 1FH (1 - 32), Initial value is 10H (17))
42H Model ID (GS)
12H Command ID (DT1)
40H Address MSB
00H Address
7FH Address LSB
00H Data (GS reset)
41H Checksum
F7H EOX (End Of Exclusive)
* When this message is received, Rx.NRPN will be ON.
* There must be an interval of at least 50 ms between this message and the next.
Universal Non-realtime System Exclusive Message
Identity Request Message
Status
Data byte Status
F0H 7EH, dev, 06H, 01H F7H
Byte Explanation
F0H Exclusive status
7EH ID number (Universal Non-realtime Message)
dev Device ID (dev: 10H - 1FH, 7FH)
06H Sub ID#1 (General Information)
01H Sub ID#2 (Identity Request)
F7H EOX (End Of Exclusive)
* When this message is received, Identity Reply message will be transmitted.
Universal Realtime System Exclusive Messages
Master Volume
Status
Data byte Status
F0H 7FH, 7FH, 04H, 01H, llH, mmH F7H
Byte Explanation
F0H Exclusive status
7FH ID number (universal realtime message)
7FH Device ID (Broadcast)
04H Sub ID#1 (Device Control)
01H Sub ID#2 (Master Volume)
llH Master Volume lower byte
mmH Master Volume upper byte
F7H EOX (End Of Exclusive)
* The lower byte (llH) of Master Volume will be handled as 00H.
Master Fine Tuning
Status
Data byte Status
F0H 7FH, 7FH, 04H, 03H, llH, mmH F7H
Byte Explanation
F0H Exclusive status
7FH ID number (universal realtime message)
7FH Device ID (Broadcast)
04H Sub ID#1 (Device Control)
03H Sub ID#2 (Master Fine Tuning)
llH Master Fine Tuning LSB
mmH Master Fine Tuning MSB
F7H EOX (End Of Exclusive)
mm, ll: 00 00H - 40 00H - 7F 7FH (-100 - 0 - +99.9 [cents])
Master Coarse Tuning
Status
Data byte Status
F0H 7FH, 7FH, 04H, 04H, llH, mmH F7
Byte Explanation
F0H Exclusive status
7FH ID number (universal realtime message)
7FH Device ID (Broadcast)
04H Sub ID#1 (Device Control)
04H Sub ID#2 (Master Coarse Tuning)
llH Master Coarse Tuning LSB
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roland E-09 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roland E-09 in the language / languages: English as an attachment in your email.

The manual is 0,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Roland E-09

Roland E-09 User Manual - Dutch - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info