528006
68
Zoom out
Zoom in
Previous page
1/88
Next page
68
Connecting to Other Devices
When you have a MIDI sequencer connected, set this
parameter to Local Off.
Since the Thru function of your sequencer will normally be
turned on, notes played on the keyboard or played back by
the recorder will be transmitted to the sound generator by
the two routes (1) and (2) shown in the illustration, causing
notes to be sounded in duplicate or to be cut off unnaturally.
To prevent this, the setting called “Local Off” is used to
disconnect the route in (1).
fig.aaaa
Local On:
The keyboard and recorder are connected to the internal
sound generator.
fig.aaaa
Local Off:
The keyboard and recorder are not connected to the internal
sound generator. No sound will be produced by the
keyboard when it is played.
fig.aaaa
1. Enter Function mode, choose “L. Ct”(p. 52).
2. Press the [-] or [+] button to switch “On” or “OFF.”
This setting specifies the MIDI channel on which the DP990F
will transmit. MIDI uses sixteen “MIDI channels,” which are
numbered 1 through 16. By connecting MIDI devices and
specifying the appropriate MIDI channel for each device, you
can play or select sounds on those devices.
The DP990F will receive all sixteen channels (1–16).
1. Enter Function mode, choose “Ch” (p. 52).
2. Press the [-] or [+] button to edit the setting.
When set to “OFF,” none of the data describing what
you play on the keyboard will be transmitted.
When Composer MIDI Out is “On,” you can send
performance data recorded with the DP990F to a connected
MIDI device or computer.
1. Enter Function mode, choose “Out”(p. 52).
2. Press the [-] or [+] button to switch “On” or “OFF.”
Preventing Doubled Notes When
Connected to a Sequencer (Local Control)
(1)
MIDI
MIDI
MIDI
MIDI
(2)
IN
IN
OUT
OUT
Sequencer
Memory
Sound
Each note played is sounded twice
Soft Thru On
Local On
Generator
Local On
Sound is emitted
Sound Generator
Local Off
No sound produced
Sound Generator
Setting
Description
On
The Local Control is set to On.
The keyboard and recorder are connected to the
internal sound generator.
OFF
The Local Control is set to Off.
The keyboard and recorder are not connected to the
internal sound generator. Playing the keyboard or
playing back a song will not produce sound.
MIDI Transmit Channel Settings
(MIDI Transmit Channel)
Setting (Channel)
OFF, 1–16
Sending Recorded Performance Data to a
MIDI Device (Composer MIDI Out)
Setting
Description
On
Performance data is transmitted.
OFF Performance data is not transmitted.
DP990F_e.book 68 ページ 2010年1月14日 木曜日 午後11時29分
68


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roland DP990F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roland DP990F in the language / languages: English as an attachment in your email.

The manual is 7,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Roland DP990F

Roland DP990F User Manual - Dutch - 83 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info