Synchronization settings
Synchronization settings for multiple DA-PCI units
Up to four DA-PCI units can be used simultaneously in one computer. Each
DA-PCI will be assigned a number from 1 through 4, following the order in
which the cards are detected. (Usually, such detection occurs in numerical
order, beginning with the lowest-numbered PCI slot.) Settings for each card
are made from the DA-PCI control panel. When using multiple DA-PCI units
simultaneously, all cards and PCI devices must be synchronized.
Synchronizing multiple DA-PCI units
In order to synchronize multiple DA-PCI units, the sampling frequency of all
DA-PCI and DA-2496 units must match, and they must be using the same
word clock. As shown below, there are two ways in which the word clock can
be shared.
1. Supplying the word clock via PCI
The word clock is supplied to multiple DA-PCI units via the DA-2496. For
each slave DA-PCI (units to which the word clock is being supplied), set the
master clock to Ext. Clock.
2. Using the included clock cable to supply the word clock
The word clock is supplied to multiple DA-PCI units via the clock cable. In
this case, use the included clock cable to connect the Clock Out connector of
the master unit (INTERNAL) to the Clock In connector of the slave unit
(EXTERNAL). On each slave (EXTERNAL) DA-PCI unit, set the master clock
setting to Ext. Clock.
Simultaneous use of
multiple DA-PCI units is
not supported for
Windows 2000 and
Macintosh.
For details on the Control
Panel, refer to DA-PCI
Control Panel (p. 32).
Word Clock
DA-PCI Cable
DA-PCI Cable
POWER
DIGITAL
ANALOG
OPTICAL
7 85 6
4
Hi
-
Z VOLUME
-
20dBu
+
4dBu
2
PHANTOM
48V
SENS PHONES
DA
-
2496
24Bit 96kHz
8IN/ 8OUT AUDIO
/
EXT
INT
CLOCK
ON
OFF
3
Hi
-
Z
PEAK
SENS
PEAK
SENS
PEAK
SENS
PEAK
SENS
PEAK
SENS
1
1
2
3456
7
8
PEAK
OUTPUT
POWER
DIGITAL
ANALOG
OPTICAL
7 85 6
4
Hi
-
Z VOLUME
-
20dBu
+
4dBu
2
PHANTOM
48V
SENS PHONES
DA
-
2496
24Bit 96kHz
8IN/ 8OUT AUDIO
/
EXT
INT
CLOCK
ON
OFF
3
Hi
-
Z
PEAK
SENS
PEAK
SENS
PEAK
SENS
PEAK
SENS
PEAK
SENS
1
1
2
3456
7
8
PEAK
OUTPUT
INT
EXT
INT
EXT
If a clock cable is
connected to the Clock In
connector, the clock from
the Clock In connector will
take priority. If you want
to supply the word clock
via PCI, disconnect the
clock cable.
If you are using a sampling
frequency of 88.2 kHz or
96 kHz, it is not possible to
synchronize multiple DA-
PCI units via a clock cable.
Please supply the word
clock via the PCI cable.
POWER
DIGITAL
ANALOG
OPTICAL
7 85 6
4
Hi
-
Z VOLUME
-
20dBu
+
4dBu
2
PHANTOM
48V
SENS PHONES
DA
-
2496
24Bit 96kHz
8IN/ 8OUT AUDIO
/
EXT
INT
CLOCK
ON
OFF
3
Hi
-
Z
PEAK
SENS
PEAK
SENS
PEAK
SENS
PEAK
SENS
PEAK
SENS
1
1
2
3456
7
8
PEAK
OUTPUT
POWER
DIGITAL
ANALOG
OPTICAL
7 85 6
4
Hi
-
Z VOLUME
-
20dBu
+
4dBu
2
PHANTOM
48V
SENS PHONES
DA
-
2496
24Bit 96kHz
8IN/ 8OUT AUDIO
/
EXT
INT
CLOCK
ON
OFF
3
Hi
-
Z
PEAK
SENS
PEAK
SENS
PEAK
SENS
PEAK
SENS
PEAK
SENS
1
1
2
3456
7
8
PEAK
OUTPUT
Clock Cable
Clock Out
Clock In
INTINT
EXTINT
DA-PCI Cable
DA-PCI Cable
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roland DA-2496 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roland DA-2496 in the language / languages: English as an attachment in your email.

The manual is 1,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info