As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows.
- The wire which is coloured green and yellow must be connected to the terminal in the plug which is
marked with the letter E or by the earth symbol or coloured green or green and yellow.
- The wire which is coloured blue must be connected to the terminal which is marked with the letter N
or coloured black.
- The wire which is coloured brown must be connected to the terminal which is marked with the letter
L or coloured red.
ATTENTION: Do not forget to use adequate plugs to the support brackets. Enquire after the manu-
facturers. Do an embedding if necessary. The manufacturer accepts no responsibility in case of a
faulty hanging due to the drilling and the setting up of plugs.
1) To carry out all the numbered operations from 1 to 16 as described starting from page 46.
2) Fixing the canopy: Before starting to x the canopy it will be necessary to adjust the support brack-
ets by turning the adjustment screws Vr in a clockwise direction until their reach their limit (Fig.3a
& b). Small adjustments can be made using the hood adjustment screws. The hood should have
a maximum excursion of 16 mm. Hook the canopy onto the two size 4.2 x 44.4 screws 1 tted as
described above (point 12). Level the hood by turning the adjustment screws and then locking the
screws 1.
3) Ducting:
The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker
hood is ducted to the outside, charcoal lters are not required.The ducting used must be 150 mm (6
INS), rigid circular pipe and must be manufactured from re retardant material, produced to BS.476
or DIN 4102-B1. Wherever possible use rigid circular pipe which has a smooth interior, rather than
the expanding concertina type ducting.
Maximum length of ducting run:
- 4 metres with 1 x 90° bend.
- 3 metres with 2 x 90° bends.
- 2 metres with 3 x 90° bends.
The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and
ducting kits are optional accessories and have to be ordered, they are not automatically supplied
with the chimney hood.
IN THE EXTRACTION MODE:
a. Place the anti-backow ats item 8 over the round outlet item 6 and connect the ducting 150mm (6
INS) over the round outlet item 6 on top of the canopy and secure the connections with appropriate
clamping rings or adhesive tape (Fig. 5).
b. Remove the grease lters (see paragraph Maintenance) being sure that the connector of the mains
cable is correctly inserted in the socket placed on the side of the fan. Before tting the chimney to
the canopy make the electrical connection as described in the section titled ELECTRICAL. When
the electrical connection has been made, test the lights and the fan motor.
c. Upper chimney stack
to urge the higher edge of the two sides of the upper chimney stack in the slits of the bracket (Point 17).
Slightly widen the two sides of the upper chimney stack (Fig.5 - Item 7a) and hook them behind the
brackets item 2 making sure that they are well seated.
d. Lower chimney stack
•Slightly widen the two sides of the chimney stack (Fig. 5 - Item 7b) and hook them between the upper
chimey stack and the wall, making sure that they are well seated.
IN THE RECIRCULATION MODE:
a. Fit the recirculation spigot bracket item 4 onto the upper chimney wall bracket using the same xing
screws (Fig.7 - item 2). Put the spigot item R into the spigot bracket item 4• Insert the connection
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roblin Odalia at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roblin Odalia in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 2,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info