490267
9
Zoom out
Zoom in
Previous page
1/52
Next page
7
GB
or injury and would deem the manufacturers guarantee null and void.
IMPORTANT - The wires in this mains lead are coloured in accordance with the following code :
green / yellow : earth blue : neutral brown : live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows.
- The wire which is coloured green and yellow must be connected to the terminal in the plug which is
marked with the letter E or by the earth symbol
or coloured green or green and yellow.
- The wire which is coloured blue must be connected to the terminal which is marked with the letter N
or coloured black.
- The wire which is coloured brown must be connected to the terminal which is marked with the letter
L or coloured red.
ATTENTION: Do not forget to use adequate plugs to the support brackets. Enquire after the manu-
facturers. Do an embedding if necessary. The manufacturer accepts no responsibility in case of a
faulty hanging due to the drilling and the setting up of plugs in the ceiling.
It is necessary to provide an adequate thermal isolation in case the blower is placed in particularly
cold rooms.
• The Hood can be tted onto the lower surface of the wall furniture. (650 mm min. from the surface of the
cooking appliance to the underside of the cooker hood.)
• To carry out a cutting (embedding) on the lower surface of the wall furniture, as indicated.
• To drill the outlet onto the top or the back of the wall furniture.
• To x the 2 squares using the provided screws.
• To place the anti-backowats item 9 over the round outlet. To secure the connections with appropriate
clamping rings or adhesive tape.
• To place the hood into the embedding and t it on the 2 squares using the 4 screws supplied.
• DUCTING
The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker
hood is ducted to the outside, charcoal lters are not required.
The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from re retard-
ant material, produced to BS.476 or DIN 4102-B1. Wherever possible utilise rigid circular pipe which has
a smooth interior, rather than the expanding concertina type ducting.
Maximum length of ducting run:
- 4 metres with 1 x 90° bend.
- 3 metres with 2 x 90° bends.
- 2 metres with 3 x 90° bends.
The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and
ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the
chimney hood.
- In the extraction mode:
• To connect the round outlet of the hood via a rigid or exible duct of ø 150 mm.
• To secure the connections with appropriate clamping rings or adhesive tape not provided.
• To remove the possible charcoal lte.
- In the recirculation mode: The ltered air is evacuated in kitchen through an outlet placed on the top of
furniture or the hood.
• To drill a hole of ø 155 mm on the top of furniture.
• To connect the round outlet of the hood via a rigid or exible duct of ø 150 mm to the outlet on the top of
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roblin Inspiration 520 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roblin Inspiration 520 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info