4 OPERATION
GB
Control panel
ABCD
E FGH
Button Function Display
A
Turns the suction motor on and off at the last
speed used.
Displays the speed set
B Decrease the working speed.
C Increase the working speed.
D
Activates intensive speed from any other
speed even with the motor off. This speed is
timed to run for 10 minutes, after which the
system returns to the previous speed. Suitable
to deal with maximum cooking fumes.
Displays HI and the bottom right hand spot
flashes once a second.
E
Activates the motor at a speed that allows
extraction of 100 m
3
/h for 10 minutes every
hour, after which the motor stops.
When the filter alarm is on, press the button
for approximately 3 seconds to reset the
alarm. These indications are only visible
when the motor is turned off.
Displays 24 and the bottom right hand spot
flashes, while the motor is turned on
On completing the procedure the previous
indicator is turned off:
FF indicates that the metal grease filters
need washing. The alarm is triggered
after the Hood has been in operation
for 100 hours.
EF indicates that the activated charcoal
filter needs changing and the metal
grease filters need washing. The
alarm is triggered after the Hood has
been in operation for 200 hours.
F
Activates automatic shutdown after 30’. Suit-
able to complete elimination of residual
odours. Can be activated from any position,
and is turned off by pressing the button or
switching the motor off.
Alternately displays the working speed and
the time remaining before the hood turns
off. The bottom right hand spot flashes.
G
H
Turns the main lighting system on and off.
Turns the ambiance lighting system on and off.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Roblin Eclat 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Roblin Eclat 2 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info