744716
9
Zoom out
Zoom in
Previous page
1/12
Next page
|9
EN
8
2. MODES
Note
When operating correctly, the stove may not be overheated. However
improper operation can shorten the life expectancy of electrical components
(blowers, motors and electrical control) and is not allowed!
Operation Modes Manual/Automatic/Comfort
MANUAL MODE
The pellet burner start and stop (ON / OFF buttons) and set the desired heat
output (PLUS / MINUS buttons) can be done on the touch screen directly at the
HOME main menu.
AUTOMATIC MODE
The change from the operating status “STOVE OFF“ to STANDBY-status (ON
button) and from STANDBY-status to STOVE OFF (OFF button) is made by
pressing the screen buttons directly in the HOME - main menu. The desired heat
output (PLUS / MINUS buttons) is also set here.
The heating time program regulates the change between STANDBY-status and
CONTROL MODE automatically.
Tip
If no heating times are stored the icon „heating times“ flashes and the stove
remains in standby.
The pellet burner start is within the heating times.
The pellet burner stop is outside the heating times.
In the operating status STOVE OFF no automatic pellet burner start is possible,
the system is turned off.
COMFORT MODE
The change from the operating status “STOVE OFF“ to STANDBY-status (ON
button) and from STANDBY-status to STOVE OFF (OFF button) is made by
pressing the screen buttons directly in the HOME - main menu. The desired
room temperature (PLUS / MINUS buttons) is also set here.
In the COMFORT mode heating times can be activated additionally.
The pellet burner start is within the heating times (or always with heating
times deactivated) if the actual room temperature is below the desired room
temperature. In between the heating times the pellet burner starts if the actual
room temperature is below the decreasing temperature preset or if the frost
protection is activated.
The pellet burner stops either outside the heating periods, or if the actual room
temperature is higher than the desired room temperature.
In the operating status STOVE OFF no automatic pellet burner start is possible,
the system is turned off.
Convection Fan - Control
(only for devices with convection fan, except type Interno)
Settings in the Setup menu
Convection Fan
You can switch on or off the convection fan as needed.
Conv. Fan Level
from level 5 (max.) to level 1 (min.). If you continue to press the „minus“ button,
you’ll set to AUTO. The convection fan speed will be adjusted automatically
depending on the heating power (30 - 100%). This setting should be chosen
as standard.
Tip for MultiAir stoves
The manually speed settings are useful if, for example, the second room
needs to be heated up quickly or heat needs to be removed from the stove.
Conv. Fan Area
You can also adapt the convection fan speed (+/- 30% fan speed). This is applied
for manual and for the AUTO setting. The fan speed can be reduced if the noise
is perceived as too loud. Conversely, for MultiAir stoves, the performance can
be increased when generally too little heated air is passed into the next room.
Convection Fan - Model Interno
To prevent overheating of the stove, the convection fan in the model Interno
can not be switched off. Once the stove is in operation, the convection fan
starts for safety reasons. The „AUTO“ setting can not be changed. A fan speed
adjustment can still be made.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rika Touch Display V2-00 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rika Touch Display V2-00 in the language / languages: English as an attachment in your email.

The manual is 1,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rika Touch Display V2-00

Rika Touch Display V2-00 User Manual - German - 12 pages

Rika Touch Display V2-00 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info