4. TECHNOLOGY AND SAFETY FUNCTIONS
The technological advances in your new combi stove are the result of
years of testing and practical experience. The practical advantages
of your pellet stove are convincing:
Operating comfort
The microprocessor-controlled combustion regulation optimises
the interaction of flue gas blower and screw using the current
combustion chamber temperature. This guarantees optimum
combustion and operating status.
All function can be regulated centrally using the integrated operating
unit. The intuitive graphic interface permits easy operation; all the
settings can be made quickly and simply.
Top efficiency - lowest emissions
A very great heat exchange surface together with optimum
combustion air control leads to excellent fuel utilisation.
Fine continuous pellet dosing in an optimised burner pot made of
high-quality grey cast iron leads to virtually complete combustion
with very good exhaust gas values - and this is guaranteed in every
operating phase.
Note
The automatic control system means that during operation, the
flame noise, pellets dropping and actuation of the electronic
components permissible for living spaces are audible.
Pressure monitoring
The negative pressure in the combustion chamber is continuously
monitored during operation. Below a defined threshold, a correct
operation can not be guaranteed and the unit will switch off with the
fault message „NOT ENOUGH LOW PRESSURE“ for safety reason.
Note
After the occurrence of the error message, maintenance or
cleaning work necessarily has to be carried out! If the error occurs
again, a safe operation is no longer guaranteed, the service must
be informed immediately.
Note
If the stove is used in a room together with a kitchen hood it might
happen that the built-in pressure switch stops the stove. If using
the hood make sure make sure that an adequate supply of air is
ensured.
Overheating
A high temperature limiter (OTB) switches the stove off automatically
on overheating. The message „STOVE OVERHEATED“ appears.
Please take the measures in the manner described in „WARNING
AND ERROR MESSAGES. The stove is ready for operation again
after acknowledging the error message at the internal unit.
Note
Maintenance and cleaning work must be performed if overheating
occurs! If this error recurs, operation without danger is no longer
guaranteed; notify customer service immediately.
Low-temperature shutdown
The unit switches off if the stove cools below a minimum temperature.
This switch-off may occur if pellet ignition is delayed.
Electrical excess current protection
The stove has a main fuse (at the rear) to protect against excess
current
Automatic cleaning cycle
The speed of the flue gas fan is increased every hour for a short
period to blow ash from the burn pot, increasing the operational
safety. The status indicator CLEANING appears on the display.
This additional function does not replace a manual cleaning as
described in CLEANING and MAINTENANCE, as this is absolutely
necessary to do regularly.
Component monitoring
All the electrical components used are continuously monitored
during operation. If a component is defective or can no longer be
actuated correctly, then operation is stopped and a warning or error
message is issued see WARNING AND ERROR MESSAGES.
Auger motor monitoring
Too long or wet pellets as well as pellets with too high dust content
(see BRIEF INFORMATION ON FUEL PELLETS) can cause so-called
auger jammers” in the auger channel. This may also happen if the
pellets accumulate in the burn pot and the backlog reaches into
the chute. The auger motor reacts in both cases with an increased
current consumption, which causes the error message: DISCHARGE
MOTOR BLOCKED. The stove will be stopped. Please call the
customer service immediately.
Power failure (during heating)
After a brief power failure, the operating functions that were set
before the power failure, continues. If the power failure lasts longer,
the stove goes to start phase if sufficient temperature or embers are
present. If the power failure lasts too long, the stove goes into the
stop phase. The flue gas fan continues to burn any pellet residues
(approximately 10 minutes). Then it will restart automatically.
Power failure (during the initial stage)
After a brief power failure the boot process continues. If the power
failure lasts longer, the stove is in the stop phase. The flue gas fan
continues to burn any pellet residues (approximately 10 minutes).
Then it will restart automatically.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rika Revivo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rika Revivo in the language / languages: English as an attachment in your email.

The manual is 9,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rika Revivo

Rika Revivo Additional guide - English - 1 pages

Rika Revivo User Manual - German - 24 pages

Rika Revivo Additional guide - German, Dutch - 1 pages

Rika Revivo Installation Guide - Dutch - 16 pages

Rika Revivo User Manual - Dutch - 24 pages

Rika Revivo Additional guide - French, Italian - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info