744675
13
Zoom out
Zoom in
Previous page
1/24
Next page
|13
12
EN
4. TECHNOLOGY AND SAFETY FUNCTIONS
The technological advances in your new combi stove are the result of
years of testing and practical experience. The practical advantages
of your pellet stove are convincing:
Operating comfort
The microprocessor-controlled combustion regulation optimises
the interaction of flue gas blower and screw using the current
combustion chamber temperature. This guarantees optimum
combustion and operating status.
All function can be regulated centrally using the integrated operating
unit. The intuitive graphic interface permits easy operation; all the
settings can be made quickly and simply.
Top efficiency - lowest emissions
A very great heat exchange surface together with optimum
combustion air control leads to excellent fuel utilisation.
Fine continuous pellet dosing in an optimised burner pot made of
high-quality grey cast iron leads to virtually complete combustion
with very good exhaust gas values - and this is guaranteed in every
operating phase.
Note
During operation, the flame noise, pellets dropping and actuation
of the electronic components are audible due to the automatic
control.
Pressure monitoring
The negative pressure in the combustion chamber is continuously
monitored during operation. Below a defined threshold, a correct
operation can not be guaranteed and the unit will switch off with the
fault message „NOT ENOUGH LOW PRESSURE“ for safety reason.
Note
After the occurrence of the error message, maintenance or
cleaning work necessarily has to be carried out! If the error occurs
again, a safe operation is no longer guaranteed, the service must
be informed immediately.
Note
If the stove is used in a habitation together with a kitchen hood or
a ventilation (WC) it might happen that the built-in pressure switch
stops the stove. If using the hood make sure that an adequate
supply of air is ensured.
Low-temperature shutdown
The unit switches off if the stove cools below a minimum temperature.
This switch-off may occur if pellet ignition is delayed.
Electrical excess current protection
The stove has a main fuse (at the rear) to protect against excess
current.
Automatic cleaning cycle
The speed of the flue gas fan is increased every hour for a short
period to blow ash from the burn pot, increasing the operational
safety. The status indicator CLEAN appears on the display.
Only for stoves with turning grids:
Every 6 hours (interval adjustable) an additionally automatic big
cleaning cycle is performed. The stove stops, the automatic cleaning
tilts the grid and then re-ignites the stove. The status indicator BIG
CLEAN appears on the display continuously. The cleaning procedure
with tilting the grid is to convey ash and clinker from the burn pot
into the ash drawer.
Note
This additional function does not replace a manual cleaning
as described in CLEANING and MAINTENANCE, as this is
absolutely necessary to do regularly.
Note
Due to the turning grid there is a certain generation of noise during
the automatic cleaning cycle (START or BIG CLEAN.
Component monitoring
All the electrical components used are continuously monitored
during operation. If a component is defective or can no longer be
actuated correctly, then operation is stopped and a warning or error
message is issued (see MANUAL TOUCH DISPLAY.
Auger motor monitoring
Too long or wet pellets as well as pellets with too high dust content
(see BRIEF INFORMATION ON FUEL PELLETS) can cause
so-called “auger jammers” in the auger channel. This may also
happen if the pellets accumulate in the burn pot and the backlog
reaches into the chute. The auger motor reacts in both cases with
an increased current consumption, which causes the error message:
DISCHARGE MOTOR BLOCKED. The stove will be stopped.
Please call the customer service immediately.
Power failure (during heating)
After a brief power failure, the operating functions that were set
before the power failure, continues. If the power failure lasts longer,
the stove goes to start phase if sufficient temperature or embers are
present. If the power failure lasts too long, the stove goes into the
stop phase. The flue gas fan continues to burn any pellet residues
(approximately 10 minutes). Then it will restart automatically.
Power failure (during the initial stage)
After a brief power failure the boot process continues. If the power
failure lasts longer, the stove is in the stop phase. The flue gas fan
continues to burn any pellet residues (approximately 10 minutes).
Then it will restart automatically.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rika Livo RAO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rika Livo RAO in the language / languages: English as an attachment in your email.

The manual is 10,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rika Livo RAO

Rika Livo RAO User Manual - German - 24 pages

Rika Livo RAO User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info