Floor bearing capacity
Ensure that the substructure is capable of bearing the weight of the
stove prior to set-up.
Note
No modifications may be made to the firing installation. This also
leads to loss of warranty and guarantee.
Floor protection
A glass, sheet steel or ceramic plate is required, if the floor is
combustible (wood, carpet, etc.).
Flue pipe connection
Q Flue pipes pose a particular source of hazard regarding gas leaks
and fire. Get the advice of an authorised specialist company for
the layout and assembly.
Q Please observe the corresponding installation guidelines for walls
panelled with wood when connecting your flue pipes to the stove.
Q Observe the formation of flue gas (atmospheric inversion) and
draughts when the weather is unfavourable.
Q Infeed of too little combustion air can lead to smoke in the rooms
or to flue gas leaks. Hazardous deposits in the stove and chimney
may also occur.
Q If flue gas escapes, let the fire burn out and check whether all the
air inlet openings are free and the flue gas pipes and the stove
pipe are clean. If in doubt notify the master chimney sweep since
draught malfunctions may be connected to your chimney.
Stoves type 1 (BA 1):
Q Suitable for multiple occupancy. (Note the different country
regulations.)
Q These may only be operated with the combustion chamber door
closed.
Q The combustion chamber door may only be opened to add fuel
and must then be closed again otherwise other firing installations
connected to the chimney may be endangered.
Q The combustion chamber door is to be kept closed when the
stove is not in operation.
Q Fouling of the chimney i.e. deposits of highly inflammable
materials such as soot and tar and subsequently fire in the
chimney may occur if wet fuel is used and operation is damped
too much.
Q If this occurs, close the fresh air support (slider,
regulator, flaps - depending on model)! Disconnect
the mains plug at the stoves type Rikatronic.
Phone the fire brigade and get yourself and other residents out
of harm’s way.
Note
on ROOM-AIR DEPENDENT and ROOM-AIR INDEPENDENT
OPERATION:
Your stove has been tested as a room-air independent stove
according to EN 13240 and can be installed as well room-air
dependent and independent.
When installed room-air dependent in combination with room-
air installations (e.g. controlled ventilation and venting systems
(extractors etc.) it must be ensured that the stove and the room
air system are monitored and safeguarded mutually (e.g. via a
differential pressure controller etc.). The combustion air infeed of
approx. 20 m3/h must be ensured.
Please observe the respective local regulations and rules in
consultation with your master chimney sweep. For changes after
the printing of this manual, we can not assume any liability. We
reserve the right to change without notice.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rika Back at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rika Back in the language / languages: English as an attachment in your email.

The manual is 12,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rika Back

Rika Back User Manual - German - 20 pages

Rika Back User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info