744679
13
Zoom out
Zoom in
Previous page
1/24
Next page
|13
EN
12
3. INSTALLING THE STOVE
General information
Note
Assembly may only be performed by authorised specialist
companies�
Note
Please observe the regional safety and building regulations� Please
contact your master chimney sweep in this context�
Note
Only use heat-resistant sealing materials as well as corresponding
sealing strips, heat-resistant silicon and rock wool�
Note
Also take care that the flue does not project into the free cross-
section of the chimney�
Note
In case of room-air independent operation the stove pipe
connections must be tightly sealed permanently� Use a heat-proof
silicon to position the stove pipe on the conical supports of the flue
tube nozzles and for insertion in the chimney flue lining�
Note
The stove should not be pushed on unprotected floors�
Tip
Strong corrugated cardboard, cardboard or e�g� old carpet is useful
to assist assembly and as a base� The stove can also be pushed on
this cardboard or carpet�
We recommend original flue pipes from RIKA for proper connection�
Connection to the chimney
QThe device must be connected to an approved
chimney for solid fuels� The chimney must have
a diameter of min� 100 mm for pellet stoves and
130 mm -150 mm for log wood stoves depending on the diameter
of the flue pipes�
QAvoid long flue pipes to the chimney� The horizontal length of the
flue pipe should not exceed 1�5 metres�
QAvoid to many bends of the flue gas pipes� There should not be
more than 3 bends in the exhaust pipe�
QPlease use a connection with a cleaning opening�
QConnections must be made of metal and must meet the
requirements of the standard (install the connections airtight)�
QBefore installing a chimney calculation must be made� The
evidence must be performed for single occupancy to EN13384-1
and EN13384-2 for multiple occupancy�
QThe maximum draft of the chimney should not exceed 15 Pa�
QThe derivation of the flue gases must be guaranteed even during
a temporary power outage
Note
If connecting to multiple connection chimneys and depending on
country regulations, additional safety equipment is required� Your
local chimney sweep will advise you in this case
Note
Be sure to prevent condensed water from entering via the flue
connection� You may need to have a condensate ring installed -
ask your chimney sweeping expert for more information� Damages
caused by condensate are excluded from manufacturer’s warranty�
Connecting to a steel chimney
The connection must be calculated and shown with EN13384-1
and EN13384-2�
Use only insulated (double) stainless steel tubes (flexible aluminum
or steel tubes are not permitted)�
An inspection door for regular inspection and cleaning must be
present�
The flue pipe connection to the chimney has to be air-tight�
Combustion air
Every combustion process requires oxygen from the surrounding air
This so-called combustion air is removed from the living are in the
case of individual stoves without external air connections�
This air removed must be replaced in the living space� Very tightly
sealed windows and doors in modern flats may mean that too little
air replaces that used� The situation also becomes problematical due
to additional venting in flats (e�g� in the kitchen or WC)� If you cannot
feed in external combustion air, then air the room several times a
day to prevent negativce pressure in the room or poor combustion�
Feeding in external combustion air
only for devices which are able to run in room-air independent
operation�
QCombustion air must be fed to the stove from outside via a sealed
pipe for operation independent of the room air� According to
EnEV, it must be possible to shut off the combustion air pipe� The
open/closed setting must be clearly recognisable�
QConnect at the air intake either a pipe Ø 125 mm for log wood and
combi stoves, or Ø 50 mm or Ø 60 mm for pellet stoves� Fix it with
a hose clamp (not included!)� At pellet stoves with longer intake
pipes than 1 m the diameter should be increased to 100 mm� (see
RIKA range)�
QTo ensure sufficient air intake, the intake pipe should not exceed
max� 4 metres and have max� 3 bends�
QIf the line leads outside it must have a windbreak�
QIn extreme cold pay attention to icing on the air intake opening
(check)�
QIt is also possible to suction in combustion air directly from
another sufficiently vented room (e�g� cellar)�
QThe combustion air pipe must be tightly connected (adhesive or
cement) permanently to the air nozzles of the stove
QIf you do not use the stove for a long time, please close the
combustion air intake to prevent the stove from moisture�
Note
Please note that problems may arise due to updrafts in the case
of combustion air supply from an integrated chimney ventilation
shaft� If the combustion air flowing downwards is heated it may
rise and thus counter the chimney with a resistance which in turn
reduces the negative pressure in the combustion chamber� The
chimney manufacturer is to guarantee that the resistance for the
combustion air is a maximum 2 Pa even in the least favourable
operating state of the chimney�
If one or more of these conditions does NOT apply, the result is poor
combustion in the stove and negative pressure in the installation
room�
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Rika Ambia at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Rika Ambia in the language / languages: English as an attachment in your email.

The manual is 10,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Rika Ambia

Rika Ambia Installation Guide - English - 28 pages

Rika Ambia Installation Guide - English - 28 pages

Rika Ambia User Manual - German - 24 pages

Rika Ambia Installation Guide - German - 28 pages

Rika Ambia Installation Guide - German - 28 pages

Rika Ambia Installation Guide - Dutch - 28 pages

Rika Ambia Installation Guide - Dutch - 28 pages

Rika Ambia User Manual - Dutch - 24 pages

Rika Ambia Installation Guide - French - 28 pages

Rika Ambia Installation Guide - French - 28 pages

Rika Ambia Installation Guide - Italian - 28 pages

Rika Ambia Installation Guide - Italian - 28 pages

Rika Ambia Additional guide - All languages - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info