MAJESTIC PROF 90x90 - 90x100
GB
GB
GB
USER HANDBOOK
B
A
0 m 2
4
c
2
4
cm0
0 c
m
6
60
c
m
3
3
3
2
2
2
1
B
A
C
TECHNICAL SPECIFICATIONS:
Minimum water pressure : 1,5 bar
Recommended water pressure : 2-5 bar
Maximum water pressure : 5 bar
Hot water temperature : max. 70 °C
Recommended water temperature : 60 °C
Safety blocking system : 38 °C
Minimum capacity : 60ºC-8L/min
Maximum flow capacity:
Hand shower : 9 l/min
Head shower : 20 l/min
Vertical hydro massage (jets) : 17 l/min
Drain via ø40mm tube : 24 l/min
Minimum innderdiameter water supply : 15 mm
Majestic 90x90 / Majestic 90x100
RI_MP Basic board
Inlet, Outlet, Valve3, Valve4 : 12VDC @ 700mA (8.4W)
Valve 5
Buzzer : 12VDC @ 250mA
Light 12VAC : 12VAC @ 20W
Heater 1 : 230VAC @ 2kW
Heater 2 : 230VAC @ 1kW (triac-controlled)
Main Supply : 230VAC
Temp : for NTC resistor (5VDC max)
Keyboard basic 1 and 2 : for keyboard connection (5VDC max)
Keyboard prof : for keyboard prof (5VDC max)
Input 1, Input 2 : Not active 0 2.0 VDC or open
Active 6 - 20 VDC
12VDCmax @ 6 mA
Water detection system : for detecting the water level, open or ground Max 5VDC
RI_EXT Extension board
Valve 6 Valve 15 : 12VDC @ 700mA (8.4W) Maximum 3 valves On simultaneously
Relay : 24VDC or AC max 500mA alternating contact
RI_RAFM Radio module (stereo)
Antenna : Antenna signal for 50ohm systems (No DC voltage)
CD : 775mVAC (1VAC max) (No DC voltage)
Speaker L and Speaker R : 7W @ 8 ohm
Majestic (A) version
Majestic (A) version
The manufacturer refuses to accept any liability in
the following cases:
! the national guidelines and standards that apply to
earthing, potential and electrical installations in
bathrooms, are not adhered to.
! the guidelines of the national laws and standards
that apply safety in bathrooms are not adhered to
! the instructions described in this manual are not
adhered to.
The cabins are dismantled once they have been
checked in the factory, to facilitate transportation and
delivery to the room in which they will be installed. It is
recommended that all the components of the shower
cabin be checked carefully before installation. Any
damage claimed after installation will not be
covered under the warranty.
SAFETY MEASURES DURING INSTALLATION
It is recommended that the bottom of the shower tray
be covered with plastic foil and cardboard in order to
prevent remnants of solid matter from damaging the
surface of the shower cabin, or blocking the drain
outlet. For all glass plates, maintain the protective strip
and protective corners on the bottom as long as
possible during installation, primarily when resting on
the shower tray. This also applies to the glass of the
technical panel. ATTENTION: It is prohibited to use
silicones containing acetyl during the installation of
the shower cabin.
After the installation, check:
- whether the water is being drained out properly.
- for leakages if any.
- whether the union nuts of the electrical cabinet have
been tightened adequately.
- whether the cover of the electrical cabinet has been
closed properly.
- whether the cabin is functioning properly.
When pushing a PE-hose into a push-in coupling for the
second time, cut-off the damaged part in order to
prevent possible leakages.
ELECTRICAL SAFETY
The shower cabin Majestic Prof is an appliance of the
Class "I".
The cabin should have a stable and durable connection to
the mains current and to the earthing installation with a
potential equaliser.
The Prof model has functions that can be programmed
using the electronic installation.
The earthing, potential and electrical installation of
the bathroom should be efficient and should satisfy
nationally applicable laws and standards.
The Prof model should be connected to an electrical
installation which has an earth leakage circuit
breaker of 30 mA.
The proper working for the switch should be checked
periodically (test).
! The earth leakage circuit breaker should have a
resistance of less than 4 Ohms.
! The shower cabin is equipped with a terminal for a
potential equaliser for a cable of 4 to 6 mm². This is
used to obtain the potential equalisation of metal
masses.
! The connection to the mains must be made using a
cable of H05 V VF-F, tripolar, with a nominal diameter
of 3x2.5 mm² and an omnipolar switch with a contact
opening of at least 3 mm, suitable for a charge of at
least 230V and a current of 16A, and should
preferably be placed outside the bathroom.
Safety regulations for bathrooms.
Electrical sockets, lamps, switches and/or other electrical
equipment should be installed outside the danger zones
indicated in the national guidelines and standards.
The regulations forbid the location of an electrical
installation in a zone that is not suitable. The switch and
other electrical devices should be placed in an area that is
inaccessible to
the person using the shower cabin.
Zone 1
Zone 3
Zone 2
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Riho MAJESTIC Prof at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Riho MAJESTIC Prof in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 60,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info