en-22
B - Air outlet via an air duct B)
B)
Fig. 5.2
The exhaust duct should be as short and straight as possible.
To avoid noisy operation or reduced air extraction capacity, the air exhaust duct must be at least 120
mm in diameter.
Use / make wide radius bends. Tight radius bends reduce the hood extraction capacity.
Use only smooth ducts or flexible ducts in non-flammable material for the exhaust air duct.
If the exhaust air duct follows a horizontal path, maintain
a minimum downward slope of 1 cm per metre or 2°
inclination angle towards the outside. Otherwise,
condensate could trickle back into the cooker hood
motor.
Fig. 5.3
If the exhaust air is routed to an exhaust air flue, the end of the inlet fitting must be oriented in the
direction of the airflow.
If the exhaust air duct is installed through rooms at low temperature, on wall brackets, etc., a significant
temperature drop may occur in the single sections of tubing, with sweating or condensate production.
For this reason, the air exhaust duct must be insulated.
In some cases a condensate trap (available from the main construction materials suppliers) should be
installed in addition to adequate insulation.
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Respekta 90 WBZ at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Respekta 90 WBZ in the language / languages: English, German as an attachment in your email.

The manual is 10.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info