7 Electrical wiring
7.1 General connection
and safety instructions
DANGER!
All electrical installation work is to be performed
by specialist companies. Disconnect the power
supply when connecting the electrical terminals.
n We recommend that a main/repair switch be
installed close to the unit. This must be pro-
vided by the customer.
n The power supply is made at the indoor unit, a
control line to the chiller is not necessary.
n If a condensate pump, which is available as an
accessory, is used in conjunction with the unit,
the pump switch-off contact switches off the
power supply or the valve if necessary.
n The connection diagram for the alarm contact
of the condensate pump available as an acces-
sory can be found in the separate operating
manual.
n If the unit is to be operated with infrared remote
control, only connection of the unit supply
cable is required.
Proceed as follows to connect:
1. The terminal block for connection of the
supply line is located beneath the plastic
cover on the bottom right side of the unit.
This can be released by undoing the screw
on the underside of the unit.
Fig. 32: Unit supply cable cover
2. If one of the unit switch contacts is to be
used, remove the unit housing. T
o do so,
undo the screws beneath the air outlet fins. It
is then possible to remove the housing by
first pulling the underside forwards.
1
Fig. 33: Unit housing disassembly
1: Fastening screws
3. Once all corresponding contacts are con-
nected, reinstall the unit cover in reverse
order
. When doing so, make sure that the
cover on the top side of the unit latches into
the corresponding guide.
NOTICE!
Check all plug and terminal connections to
verify that they are tight and make a permanent
contact. T
ighten as required.
37
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO WLT-EC serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO WLT-EC serie in the language / languages: English as an attachment in your email.

The manual is 6,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO WLT-EC serie

REMKO WLT-EC serie User Manual - German - 60 pages

REMKO WLT-EC serie User Manual - Dutch - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info