MODE Button
Press the MODE button once or repeatedly to switch to automatic mode.
In this mode, the regulation automatically selects COOL or HEAT mode
depending on the temperature. The temperature is then maintained at
the set value.
The FAN should be set to AUTO.
Press the MODE button to change to another mode. A total of 5 modes
are available:
1. AUTO Automatic mode, automatic selection of cooling or
heating mode
2. COOL Cooling mode, mainly used in summer
3. DRY Dehumidifying mode, used in summer or winter
4. FAN Circulation mode, no cooling or heating output
5. HEAT Heating mode, mainly used in winter
MODE MODE MODE MODE
Mode AUTO
Press the MODE button once or repeatedly to switch to cooling mode.
Use this mode to cool the room air to the desired target temperature.
Press the TEMP p / q buttons to set the desired room temperature in 1
°C steps. If the room temperature is 1 °C above the desired temperature
and sufficient coolant is available, the indoor unit will start to cool the
room air. f the actual temperature falls approx. 0.5 °C below the set room
temperature, the controller switches the cooling off.
Mode COOL
MODE
COOLING MODE
It is recommended that the
target temperature is set to
max. 6 °C below the outdoor
temperature. The automatic
fan speed and swing functions
should also be used.
NOTE
MODE
TEMP
Cooling
or
Heating
Set temperature
below room temperature
Set temperature
above room temperature
9
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO SV351 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO SV351 in the language / languages: English as an attachment in your email.

The manual is 3,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO SV351

REMKO SV351 User Manual - German - 32 pages

REMKO SV351 User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info