587835
52
Zoom out
Zoom in
Previous page
1/56
Next page
Technical data
Series RXT 351DC RXT 521DC RXT 681DC RXT 1051DC RXT 1401DC
Operating mode Inverter wall-mounted room air conditioner combination for cooling and heating
Nominal cooling output
1)
kW
3,51 (1,41-4,02) 5,27 (1,63-5,65) 7,03 (1,63-7,92) 10,55 (3,01-13,22) 14,01 (3,41-15,62)
Nominal heating output
2)
kW
4,02 (1,42-4,75) 5,86 (1,45-6,15) 7,76 (1,75-8,61) 11,72 (3,75-14,02) 15,47 (4,23-16,50)
Energy efficiency rating, cooling
1)
A A A A A
Energy efficiency rating EER
1)
3,55 3,34 3,22 3,25 3,24
Energy efficiency rating, heating
2)
A A A A A
Coefficient of performance COP
2)
3,76 3,86 3,66 3,87 3,62
Power consumption, yearly,
(500h) C / H
495 / 535 790 / 760 1090 / 1060 1625 / 1515 2165/2135
Usage area
(room volume), approx.
110 160 230 320 470
Refrigerant R 410A
4)
Power supply V/Hz 230 / 1~ / 50 400 / 3~ / 50
Rated electr. power
consumption, cooling
1)
kW
0,99 (0,32-1,27) 1,58 (0,44-2,32) 2,18 (0,84-2,35) 3,25 (2,31-5,02) 4,33 (2,51-5,95)
Rated electr. power
consumption, heating
2)
kW
1,07 (0,36-1,38) 1,52 (0,36-2,44) 2,12 (0,72-2,72) 3,03 (2,03-5,91) 4,27 (1,45-5,51)
Max. rated electr. power
consumption
kW
2,55 2,40 3,25 5,00 5,50
Rated electr. current
consumption, cooling
1)
A
4,67 (1,68-5,90) 7,09 (1,95-10,50) 10,30 (3,65-11,52)
4,72 (3,80-7,53) 6,27 (3,80-8,83)
Rated electr. power
consumption, heating
2)
A
5,05 (1,89-6,41) 6,81 (1,65-11,60) 10,05 (3,22-12,81) 4,47 (3,49-8,98)
6,19 (2,18-8,48)
Electr. starting current, max. A 12 14 15,5 7,5 7,8
Refrigerant connection,
injection line
Inches
(mm)
1/4 (6,35) 1/4 (6,35) 3/8 (9,52) 3/8 (9,52) 3/8 (9,52)
Refrigerant connection,
suction line
Inches
(mm)
1/2 (12,70) 1/2 (12,70) 5/8 (15,90) 5/8 (15,90) 5/8 (15,90)
Max. operating pressure kPa
4200 / 2500
Data specific to indoor unit
RXT 351DC IT RXT 521DC IT RXT 681DC IT
RXT 1051 DC IT
RXT 1401DC IT
Setting range for room temperature
°C +17 to +30
Operating range °C +17 to +32
Air flow volume per speed setting
m³/h 460/520/580 500/600/800 960/1080/1150
1000/1200/1400
1600/1800/2000
Sound pressure level per speed setting
3)
dB(A) 33/37/40 38/41/43 40/43/46 42/44/47 44/46/47
Protection class IP X0
Condensation connection mm 25
Dimensions - Height mm 660 660 660 660 680
Width mm 990 990 990 1280 1670
Depth mm 206 206 206 206 245
Weight kg
18,0 29,0 29,0 37 52
Data specific to outdoor
component
RXT 351DC AT RXT 521DC AT RXT 681DC AT
RXT 1051DC AT
RXT 1401DC AT
Operating range, cooling °C +5 to +43
Operating range, heating °C -15 to +24
Air flow rate, max. m³/h 1600/2500 2300/2570 3000/3250 4800/5000 5800/6000
Protection class IP 24
Sound pressure level, max.
3)
dB(A) 48 51 53 55 58
Refrigerant, basic quantity kg 1,40 1,60 2,30 2,9 3,6
Refrigerant, additional quantity > 5 m
g/m 30 30 30 30 30
Refrigerant pipe, max. length
m 15 25 25 30 50
Refrigerant pipe, max. height m 10 10 10 20 20
Flow regulator Capillary tube Electronic Electronic Electronic Electronic
Dimensions - Height mm 590 675 835 940 1235
Width mm 760 845 895 990 940
Depth mm 270 325 335 335 335
Weight kg 39,0 59,0 73,0 87,0 99,0
Serial number 1034... 1035... 1036... 1037... 1038...
EDP no. 1619430 1619440 1619450 1619460 1619470
1) Air intake temperature TK 27°C / FK 19°C, outdoor temperature TK 35 °C, FK 24 °C, max. air flow volume, 5m pipe length
2) Air intake temperature TK 20°C, outdoor temperature TK 7°C, FK 6°C, max. air flow volume, 5m pipe length
3) Gap 1 m free space 4) Contains greenhouse gas according to Kyoto Protocol
REMKO RXT...DC
52
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RXT681 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RXT681 DC in the language / languages: English as an attachment in your email.

The manual is 3,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RXT681 DC

REMKO RXT681 DC User Manual - German - 52 pages

REMKO RXT681 DC User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info