Fault code
DISPLAY
Fault description Required action
E0 EEPROM error See page 36 / point 1
E2 Communication error between indoor unit and outdoor component See page 36 / point 2
E3 Communication error on outdoor component main board (for RXT 1051 DC and up) See page 37 / point 3
E4 Fault on the outdoor temperature sensor See page 37 / point 4
E5 Compressor overvoltage protection See page 37 / point 5
P0 Compressor overload protection (Klixon) tripped
P1 High pressure fault (from RVD 521 and up) See page 38 / point 6
P2 Low pressure fault (from RVD 521 and up) See page 39 / point 7
P3 Compressor overcurrent protection tripped See page 40 / point 8
P4 Hot gas temperature sensor too high See page 41 / point 9
P5 Condenser outlet sensor triggered See page 41 / point 10
P6 IPM power board safety shutdown See page 42 / point 11
Fault displays shown on the outdoor component
RXT 521-1401DC outdoor component fault analysis
1. Fault code E0: EEPROM error
No
Fit EEPROM properlyIs the EEPROM
fitted properly?
Yes
Replace outdoor
component main board
2.
Fault code E2: communication error between indoor
unit and outdoor component
No
Establish the power
supply.
Is there voltage in the
indoor unit?
Yes
Use shielded, earthed
cable
Is the connecting cable
shielded, and is it
earthed?
Yes
Is the cable connecting
the indoor unit and
outdoor component
properly connected?
No
Connect the cable
properly.
Replace the main board
for the indoor unit or
outdoor component
Yes
Is the cable connecting
the indoor unit and
outdoor component
damaged?
No
Yes
Replace the cable.
No
39
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RXT1051 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RXT1051 DC in the language / languages: English as an attachment in your email.

The manual is 3,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RXT1051 DC

REMKO RXT1051 DC User Manual - German - 52 pages

REMKO RXT1051 DC User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info