587836
35
Zoom out
Zoom in
Previous page
1/56
Next page
Is the EEPROM
fitted properly?
Fit EEPROM properly
Replace outdoor
component main board
No
Yes
5. Operation and Timer lights flash at 5 Hz:
EEPROM error
6. Operation light flashes at 5 HZ and Alarm light is on: IPM safety shutdown
Check the power
supply to the circuit
board. Is it working
OK?
Check the power
supply for the
outdoor component.
Is a voltage of 230
V present at the unit
power supply?
Check the
windings of the
compressor
No
Yes
Correct the power
supply to the unit.
Is the unit working
properly again?
No
Are the connections from the circuit board to
the compressor OK?
Yes
No
Correct
connections
Are the
windings of the
compressors
OK?
Yes
Replace
circuit board
No
Replace
compressor
No
Does the
unit run after
replacing the
compressor?
Check the unit's
electrical supply.
Is it properly
connected?
Yes
No
No
Connect the electrical
supply properly
Are all the circuit
board's electrical
cables properly
connected?
Yes
No
Connect all electrical
cables properly
Yes
Check the chokes on
the circuit board
Yes
Replace circuit board
Chokes have
resistance?
No
Check the fuses on
the circuit board
Circuit board fuses
OK?
No
Replace fuse or circuit
board
Replace circuit board
Yes
35
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RXT1051 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RXT1051 DC in the language / languages: English as an attachment in your email.

The manual is 3,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RXT1051 DC

REMKO RXT1051 DC User Manual - German - 52 pages

REMKO RXT1051 DC User Manual - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info