8 Electrical wiring
8.1 General notes
A mains cable must be installed as the power
supply to the outdoor unit and a control line to the
indoor unit, with appropriate protection.
DANGER!
All electrical installation work is to be performed
by specialist companies. Disconnect the power
supply when connecting the electrical terminals.
WARNING!
All electric lines are in accordance VDE regula-
tions to dimension and to lay
.
NOTICE!
The electrical connection for the units must be
made at a separate feedpoint with a residual
current device in accordance with local regula-
tions and should be laid out by an electrician.
W
e recommend using shielded wires for the
control lines.
Check all plugged and clamped terminals to
verify that they are seated correctly and make
permanent contact. T
ighten as required.
8.2 Connecting the indoor unit
The unit requires a six-wired control line from the
indoor unit to the outdoor unit.
n W
e recommend installing a main / repair switch
on the building close to the indoor unit. This is
the responsibility of the customer.
n Power is supplied to the outdoor unit, the
indoor unit is supplied via the control line from
the outdoor unit to the indoor unit.
n The terminal blocks for establishing the con-
nections are located inside the unit.
n If an optional condensate pump is used as an
accessory in conjunction with the unit, it may
be necessary to install an additional relay with
a higher contact rating after the switch-off con-
tact on the pump to switch off the compressor.
Make the connection as follows:
1. The connection terminal block is located on
the right inside the unit (
Fig. 39).
2. Connect the unit to the control line from the
outdoor unit. See “Electrical wiring diagram”.
3. Re-assemble the unit.
2
1
2
1
Fig. 39: Connecting the indoor unit
1: Electrical connection (terminal box)
2: Connection of refrigerant lines
33
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RXT 1055 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RXT 1055 DC in the language / languages: English as an attachment in your email.

The manual is 4,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RXT 1055 DC

REMKO RXT 1055 DC User Manual - German - 84 pages

REMKO RXT 1055 DC User Manual - Dutch - 84 pages

REMKO RXT 1055 DC User Manual - French - 84 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info