Technische Daten
RXM
226
RXM
235
RXM
252
RXM
268
RXM
326
RXM
335
RXM
426
RXM
435
Betriebsart Multisplit-Außenteile zum Kühlen
Nennkühlleistung 1) kW 5,24 7,12 10,5 13,78 8,80 10,68 10,48 14,24
Nennkühlleistung je Kältekreis 1) kW 2 x 2,62 2 x 3,56 2 x 5,25 2 x 6,89 2 x 2,62
1 x 3,56 3 x 3,56 4 x 2,62 4 x 3,56
Energieeffizienzklasse Kühlen 1) BCCBCBBC
Energieeffizienzgröße EER 1) 3,06 2,87 2,88 3,02 2,95 3,02 3,02 2,87
Energieverbrauch, Jährlich, (500h) 1) kWh 855 1240 1820 2280 1490 1770 1735 2480
Arbeitsbereich Außenteil Kühlen °C +7 bis +48
Kältemittel R 410A 3)
Betriebsdruck max. / je Kältekreis kPa 4200
Luftvolumenstrom max. m³/h 2310 4455 5665 4455 5665
Schalldruckpegel max. 2) dB (A) 50 52 54 57 55 56 55 57
Spannungsversorgung V/Hz 230V / 1~ / 50Hz 230V / 2~ / 50Hz
Schutzart IP 24
Elektr. Nennleistungsaufn. Kühlen kW 1,71 2,48 3,64 4,56 2,98 3,54 2 x 1,74 2 x 2,48
Elektr. Nennstromaufn. Kühlen A 7,50 11,40 16,30 21,10 14,26 17,74 2 x 9,0 2 x 12,0
Elektr. Nennstromaufn. Kompressor A 3,60 5,34 7,29 9,42 2 x 3,60
1 x 5,34 3 x 5,34 4 x 3,60 4 x 5,34
Elektr. Nennstromaufn. Ventilator A 0,30 0,72 2 x 0,86 2 x 1,13 2 x 0,86 2 x 0,86 2 x 0,86 2 x 1,13
Elektr. Anlaufstrom, max. A 2 x 21 2 x 28 2 x 36 2 x 51 2 x 21
1 x 28 3 x 28 4 x 21 4 x 28
Kältemittel, Grundmenge kg 2 x 0,85 2 x 1,00 2 x 1,45 2 x 1,80 2 x 0,85
1 x 1,9 3 x 1,00 4 x 0,85 4 x 1,00
Kältemittel, Zusatzmenge >5m g/m 25 45 25
Kältemittelanschluss Einspritzleitung Zoll (mm) 1/4 3/8 1/4
Kältemittelanschluss Saugleitung Zoll (mm) 3/8 1/2 5/8 2 x 3/8
1 x 1/2 1/2 3/8 1/2
Kältemittelleitung, Länge max. m25
Kältemittelleitung, Höhe max. m15
Abmessungen Höhe mm 615 1240
Breite mm 845 830 930 830 930
Tiefe mm 285 310 390 310 390
Gewicht kg 52 56 115 125 95 97 110 130
Seriennummer 835... 836... 837... 838... 839... 840... 841... 842...
EDV-Nr. 1625200 1625210 1625220 1625230 1625300 1625310 1625400 1625410
1) Außentemperatur TK 35°C / FK 24°C, max. Luftvolumenstrom, 5m Rohrleitungslänge in Kombination mit RXW 261-681
2) Abstand 1 m Freifeld
3) Enthält Treibhausgas nach Kyoto-Protokoll
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RXM426 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RXM426 in the language / languages: German as an attachment in your email.

The manual is 2,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info