“Intelligent eye” key
Press the “Intelligent eye” key to activate the auto-
matic wind direction change. The unit will then
direct the air flow onto a person in the room.
Pressing the key again deactivates the following
setting. The fan flaps remain in the current posi-
tion. Pressing the key a third time deactivates this
function. Note: The “Intelligent eye” is deactivated
by any key press. The exceptions are the “T
imer”
[4] and “LED” [5] keys. If the room temperature
exceeds 32 °C, this function is not available. If
there are two or more persons/moving objects
within the acquisition range of the Intelligent eye,
this function cannot be used.
1
3
2
4
a
b
c
1 m
8 m
1: Wall
2: Indoor unit
3: Intelligent eye
4: Acquisition range
a: Left - 75° ±10°
b: Centre - 30° ±10°
c: Right - 75° ±10°
9
“+” key
Press this key to increase the setpoint in steps of
0.5 °C up to a maximum of 30 °C.
10
Fan speed & silence mode
Use this key to select the desired fan speed.
Note: In the dehumidification mode, the fan speed
cannot be set manually
.
The fan speed can be set in 5 stages by pressing
the key: 20%,40%,60%,80%,100%. Press the
“Fan” key and then “+” or “-” to increase or
decrease the fan speed in steps of 1%. Press and
hold the key for 2 seconds to activate silence
mode. The unit then reduces its output to minimise
the amount of noise.
11
“-” key
Press the key to reduce the setpoint in steps of 0.5
°C as far as the minimum of 16 °C.
Pressing the “-” key twice within a second again
deactivates the frost protection function. This can
only be activated in heating mode, and is set to a
fixed setpoint of 8 °C. “FP” then appears on the
display of the indoor unit. This function is deacti-
vated by pressing the "On/Of
f", "Mode", "+" , "-" or
"Fan" key.
12
3-D swing mode, horizontal
Press this key to start horizontal swing mode.
Press this key once to change the angle of the fin
by 6 degrees. Pressing the key for two seconds
stops the swing function. Stop the swing function
by briefly pressing the key
.
13
3-D swing mode, vertical
Press this key to start vertical swing mode. Press
this key once to change the angle of the fin by 6
degrees. Pressing the key for two seconds stops
the swing function. Stop the swing function by
briefly pressing the key.
14
"SELF CLEAN" key
The self-clean function can be activated in the
cooling or dehumidification mode. It is used to dry
the evaporator after long operating periods. This is
to prevent mould and odours. The unit enters recir-
culation mode for a short time after activation,
heats up briefly after a few minutes and then
switches back to recirculation mode.
21
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RVT 355 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RVT 355 DC in the language / languages: English as an attachment in your email.

The manual is 4,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RVT 355 DC

REMKO RVT 355 DC User Manual - German - 76 pages

REMKO RVT 355 DC User Manual - Dutch - 76 pages

REMKO RVT 355 DC User Manual - French - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info