726821
32
Zoom out
Zoom in
Previous page
1/44
Next page
Electrical drawings RVS 180 DC
Pressure sensor
ET)
0
A
B
C
D
E
F
A
B
C
D
E
F
Pressure sensor
SUT
2 3 4 5
6
N
L1
L1
N14
K2
RO 18
RO 17
RO 16
RO 15
RO 14
RO 13
RO 12
RO 11
RO 10
RO 09
RO 08
RO 07
RO 06
RO 05
RO 04
RO 03
RO 02
RO 01
L
N
DI 09
DI 10
D01- PWM
A01
D02- PWM
A02
DI2- PWM
D03- PWM
DI1- PWM
DI3- PWM
D04- PWM
DI4- PWM
D05- PWM
DI5- PWM
DI 08
DI 07
DI 06
DI 05
DI 04
DI 03
DI 02
DI 01
AI 22
AI 21
AI 20
AI 19
AI 18
AI 17
AI 16
AI 15
AI 14
AI 13
AI 12
AI 11
AI 10
AI 09
AI 08
AI 07
AI 06
AI 05
AI 03 (50K)
AI 02
AI 01
AI 04 (50K)
SUT
AT
ET
OT
IT
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
t
5K
t
5K
IT
OT
t
50K
ET
t
5K
SUT
t
5K
AT
HP
HP
LP
LP
FS
FS
4
485A+
485B-
4V
4V
7 8 9 1 0 1 1 1 2
12
8
10 7 1
5 4
10 12
L3(C)
L2(B)
L1(A) 11
14
12
N
L1
L2
L3
N14
N
1 3
2 4
5
6
7
8
01
N
N
21
22
485A+
485A+
485B-
485B-
t
5K
CT
CT
L1
L2
L3 N
RED
BLK
WHT
BLU
Y/G
400V/3N~/50Hz
RED RED WHT
BLK BLK WHT YEL
RED
18
Remote
ON/OFF
17 18
17 18
1
1 7 8
BLK
6
9
N
19
20
Remote
Heat/Cool
19 20
19 20
Controller
K2
3
PUMPE
U
V
W
L1
L2
L3
BRN BLK BLU
L1
L2
L3
FR
Y/G
L1
L2L3
YEL
RED
BLK
GND
485-A1
485-B1
12V
CAN-L
CAN-H
12V
GND
GND
5V
GND
485-B2
12V
GND
485-B3
12V
485-A2
48 5-A3
4
BLU
4
30
YEL
WHT
BLK
N
D CN- IN
CN613
U V W
COMP
U
V
W
R S T
DC P-IN
CN 614
DC N-OUT
CN 615
DCP-OUT
CN617
B
A
GND
12V
CN 602
GND
CN 605
5V
J P60 1
39K
1 3
2 4
5
6
7
8
02
RED
BLK
WHT
39K
16
13
14
N9
15
16
220V~
Electric heat
relay coil
220V~
Alarm
out
17
CN 1
L
N
GN D
L1
30
4
N
L1
FM1
485 A1
12 V
485 B1
YEL
WHT
BLK
FM2
CN 4
N
FU
1A
L1
L2
L3
N1
K2
K2
N
4V
CH
CH CH
H C
PH
L1
L1
N
N
N
WHT
3 4 5
6
3
EEV
5
CN3 CN4
CN1 CN2
Q
L1
L2
L3
L1
L2
L3 N
L1L2
L3N
N- C- B- A-
N
L1
L2
L3
N
16
N
FR
N
MTS
COMPKompre ssor/Compressor
FSStrömungswächter/Flow switch
ITSen sor Mediu m Eintritt/ Inlet water tempe ratu re
OTSen sor Mediu m Austritt
/Outlet water temperature
CTSen sor Verflüssiger /Coil temperature
4V Umkehrventil / 4 way valve
HPHD-Schalter/High pressure protection
FUSicheru ngen/Fuse
CHKW-Heizung/Compressor heater
LPND-Sc halter/Low pressure protection
Freigabekonta kt potentialfr ei/REMOTE ON/OFF
Umschaltkontakt K/H poten tialfrei/REMOTE HEAT/COOL
Sammelsrmeld. potentialfrei/Alar m out
SUTSuction te mperature
Relaisspule der elektrischen Zusatzheizu ng/Electric heat relay coil
K2Schütz Umwä lzpumpe /Cont actor Circulation Pump
ETExhaus t temperature
EEV
Electronic expand valve
FRMotorschutzscha lter/Thermal relay
PHAbtauheizung / Defrost heater
MTSTermperaturre gler Heizu ng/ Tem perature switch
1
2
3
4
5
6
7
8
9
Geräte s c h u t z s chalter
Filter p l a t i n e
C B A
Platin e D rehzahlregelu n g
Invert e r - P l a t ine
Gleich r i c h t e r
Verdichter-
Hauptp l a t i n e
Phasen f o l g e r e lais
REMKO series RVS
32
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RVS DC serie 50-80-130-180 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RVS DC serie 50-80-130-180 in the language / languages: English as an attachment in your email.

The manual is 3,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RVS DC serie 50-80-130-180

REMKO RVS DC serie 50-80-130-180 User Manual - German - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info