726584
11
Zoom out
Zoom in
Previous page
1/84
Next page
Associated outdoor unit / series
RVD 355 DC
A
T
RVD 525 DC
AT
RVD 685 DC
AT
RVD 1055 DC
AT
Power supply V/Ph/Hz 230/1~/50 400/3~/50
Operating range, cooling °C
+5 to +50
7)
Operating range, heating °C
+5 to +24
7)
Air flow rate, max. m³/h 2000 2700 4000
Enclosure class IP 24
Sound power level max. dB (A) 63 64 68
Sound pressure level
5)
dB (A) 56 55 62 64
Refrigerant
6)
R32
Refrigerant, basic quantity kg 0.87 1.15 1.50 2.40
CO
2
equivalent
t 0.59 0.78 1.01 1.62
Operating pressure, max. kPa 4300/1700
Refrigerant, additional quantity
>5m
g/m 15 30
Refrigerant piping, max. length m 25 30 50 65
Refrigerant piping, max. height m 10 20 25 30
Refrigerant connection,
liquid pipe
Inches
(mm)
1/4 (6.35) 3/8 (9.52)
Refrigerant connection,
suction pipe
Inches
(mm)
3/8 (9.52) 1/2 (12.7) 5/8 (15.9)
Dimensions:
Height / width / depth
mm 554/800/333 702/845/363 810/946/410
Weight kg 34.7 33.7 49.4 81.5
EDP no. 1623846 1623856 1623866 1623876
5)
At distance of 1 m in the open air; specified values are maximum values
6)
Contains greenhouse gas per the Kyoto protocol, GWP 675 (for further information, see chapter "Adding refrigerant")
7)
Can be expanded up to -15 °C with optional winter fan speed control
11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RVD 1055 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RVD 1055 DC in the language / languages: English as an attachment in your email.

The manual is 5,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RVD 1055 DC

REMKO RVD 1055 DC User Manual - German - 84 pages

REMKO RVD 1055 DC User Manual - Dutch - 84 pages

REMKO RVD 1055 DC User Manual - French - 84 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info