587574
11
Zoom out
Zoom in
Previous page
1/20
Next page
Shut-down
Temporary shut-down
If it is planned to shut down the
equipment for longer periods e.g.
during the winter, proceed as fol-
lows:
1. Allow the equipment run for
2-3 hours in circulation mode.
This extracts any residual hu-
midity from the unit.
2. Shut down the equipment by
pressing the "I / 0" button on
the operating panel. Only then
The unit has been manufactured using state-of-the-art production methods and tested several times to ensure
its correct function. If malfunctions should occur, please check the unit as detailed in the list below. If all func-
tional checks have been carried out and the device still fails to operate properly, then please notify your nearest
specialist dealer.
Troubleshooting and customer service
Fault Possible cause Remedial measures
The unit does not start
Mains failure
Check voltage and if necessary wait until
power is back on
Mains fuse or controller fuse faulty Arrange to have exchanged
Mains plug not inserted in socket Insert mains plug
Condensate container full, display "DRAIN
WATER" flashes
Empty container via condensate drain hose
Timer mode active
Wait for timer period to expire or
press "I / 0" button again
The unit is running with
Reduced ventilation output
Used air or outlet openings soiled or blocked
by foreign bodies
Clean the openings
Remove foreign bodies
Filter soiled
Clean the filter in accordance with the instructions
Outdoor unit soiled
Clean the fins on the inside of the outdoor
unit
Cooling load of the room excessive Reduce the thermal load
Condensate leaks out of
the unit
Device standing at an angle Position vertically, ensure stable positioning
Plugs missing from condensate
drain hose
Seal the hose so that it is watertight again
should you pull out the mains
plug and wind up the cable.
3. Empty the internal condensate
container via the condensate
drain hose on the rear side of
the indoor unit.
4. Make sure that there is no
condensate in the outdoor unit
before storing the indoor and
outdoor unit indoors. To drain
the condensate, remove the
plug from the outdoor unit.
5. Clean the filter and the plastic
surfaces.
6. Hang the outdoor unit onto the
indoor unit.
7. Cover the equipment with
a synthetic tarpaulin to protect
it against dust.
8. Store the equipment in a cool
and dry location away from
direct sunlight.
Permanent shut-down
The entire system should only be
dismantled by a specialist firm
familiar with all environmental
aspects involved.
REMKO GmbH & Co. KG or your
sales partner will be be pleased to
provide details of refrigerant spe-
cialists in your area.
Never switch off the equip-
ment by pulling out the mains
plug.
NOTE
11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RKL490 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RKL490 DC in the language / languages: English as an attachment in your email.

The manual is 1,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RKL490 DC

REMKO RKL490 DC User Manual - German - 16 pages

REMKO RKL490 DC User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info