587573
11
Zoom out
Zoom in
Previous page
1/16
Next page
11
13. Screw the supplied protective caps onto the 4 cou-
pling halves (Fig. 16).
14. Provide for a wall lead-through Ø 60 mm .
15. After setup or assembly of the indoor unit and out-
door unit, the connecting line is attached to the in-
door unit in the reverse order (Points 12 to 1).
16. After attaching the connection, make sure that the
couplings are tightly sealed.
Cleaning the Dust Filter
The indoor unit is equipped with an dust filter. It can be
pulled out of the back of the unit. The dust filter must be
cleaned at regular intervals.
To clean the dust filter, proceed as follows:
1. Remove the dust filter. (Fig. 17).
2. Clean the dust from the filter.
If the filter is only slightly dirty, you can use a vac-
uum cleaner.
The unit may only be cleaned with a clean, soft and
slightly damp cloth which is used to carefully wipe the
dirt from the surface.
Only use warm water.
Maximal 40 °C warm.
Thoroughly clean the air output and intake openings
on a regular basis.
In our experience, this is the first place where dirt
accumulates.
Never forget to clean the water tank on a regular basis.
Do not use aggressive cleansers or cleaning prod-
ucts containing solvents.
Never clean the unit under a stream of water.
3. If the dust filter is very dirty, clean it carefully in
warm water.
4. Then let the filter air dry.
5. Reinsert the filter into the unit
In case of extreme dirt the dust filter is to be replace.
Never use the unit without installed dust filter!
Without a dust filter the plate fins of the evapora-
tors would become dirty and the capacity of the
unit would be decreased.
Fig. 17
Dust filter
Comments about detaching the connection line:
The units may only be detached right before mount-
ing and they should only remain disconnected as
long as absolutely necessary.
Before the lines are reconnected, make sure that no
dirt, moisture or other foreign matter has adversely
affected proper functioning of the couplings.
Reattach the fastening clamp after the lines have
been connected.
The lines should only be detached and reconnected
by authorised personnel.
The unit can be detached and reconnected approxi-
mately 10 times when done properly without any
noticeable decline in cooling performance.
Fig. 16
Protective
caps
Protective
caps
Maintenance and Service
Regular care and the observation of a number of basic
rules will ensure the dehumidifier’s long service life and
reliable operation.
The unit should be inspected and cleaned thoroughly
after each long period of operation, at a minimum once
a year.
All moving parts have been permanently lubricated.
The complete cooling system is a closed-loop system
that requires little maintenance. It may only be ser-
viced by authorised repair centres.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RKL480 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RKL480 in the language / languages: English as an attachment in your email.

The manual is 1,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RKL480

REMKO RKL480 User Manual - German - 16 pages

REMKO RKL480 User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info