726575
18
Zoom out
Zoom in
Previous page
1/28
Next page
8 Troubleshooting
The unit has been manufactured using state-of-the-art production methods and has been tested several
times to ensure that it works properly
. If malfunctions should occur, please check the unit as detailed in the
list below. Please inform your dealer if the unit is still not working correctly after all the function checks have
been performed.
Operational malfunctions
Fault description Cause Remedy
The unit does not start Power failure Check voltage and if necessary wait
until turned on again
Mains fuse or controller fuse
faulty
Arrange to have exchanged
Power plug not inserted in
socket
Insert power plug
Condensate container full,
"DRAIN W
ATER" display
flashes
Empty container via the condensate
drain hose
Timer mode activated Wait for timer period to expire or press
"I / 0" key again
The unit is working with reduced
performance
Exhaust air or outlet openings
are dirty or blocked by foreign
bodies
Clean the openings, remove foreign
bodies
Filter soiled Clean the filter in accordance with the
instructions
Outdoor unit soiled Clean the fins on the inside of the out-
door unit
Cooling load of the room
excessive
Reduce the thermal load
Condensate leaks out of unit Unit standing at an angle Position vertically, ensure stable base
Stopper in condensate drain
hose missing
Seal the hose so that it is watertight
again
Error indication by code
If the following alarm codes appear, please contact your dealer:
Error code Error description Possible cause/remedy
01# Communication error between the circuit
board on the indoor unit and outdoor unit
- Check the 6-wire connection and plug con-
tacts CN202 (PCB 2) - CN109 (PCB 3).
Replace the connecting cable if necessary
.
- Replace the motherboard (PCB 3)
02# Ambient temperature probe defective - Replace THRA probe (PCB 2)
03# Probe, evaporator defective - Replace THEP probe (PCB 2)
REMKO RKL DC series
18
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RKL 495 DC S-Line at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RKL 495 DC S-Line in the language / languages: English as an attachment in your email.

The manual is 2,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RKL 495 DC S-Line

REMKO RKL 495 DC S-Line User Manual - German - 28 pages

REMKO RKL 495 DC S-Line User Manual - Dutch - 32 pages

REMKO RKL 495 DC S-Line User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info