Fig. 13: Dismantling the connecting line
1: Connecting line
2: Fastening clip
3: Plug connection
4: Condensate hose
5: Fastening clip
9. Unscrew the left-hand union nut with the size
24 open-ended spanner provided. In doing
so, use the second size 21 open-ended
spanner to hold the lower coupling section
still (Fig. 14).
NOTICE!
Never twist the the fixed lower section.
NOTICE!
It is possible that residual fluid can leak
out of the the condensate hose.
10. Screw continuously until the connection is
disconnected.
11. Unscrew the right-hand union nut with the
size 24 open-ended spanner provided. In
doing so, use the second size 21 open-
ended spanner to hold the upper coupling
section still (
Fig. 15).
NOTICE!
Never twist the the fixed upper section.
12. Screw continuously until the connection is
disconnected.
NOTICE!
Do not stop screwing in the event that
refrigerant escapes and a slight hissing
sound is heard.
13. Screw the protective caps provided onto the
4 coupling halves (
Fig. 16).
14. Ensure that there is a wall opening available
of Ø 60 mm in the event that the connecting
line is to be fed through a wall.
15. After the placement or mounting of the indoor
unit and outdoor unit is complete, the con-
necting line can be hooked up to the outdoor
unit in the opposite order
.
16. After making the connections, check the
quick-release couplings for leaks.
A
B
C
D
Fig. 14: Unscrew the left-hand union nut
A: Hold to prevent turning
B: Tighten
C: Loosen
D: Remove fastening clip
15
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RKL 495 DC S-Line at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RKL 495 DC S-Line in the language / languages: English as an attachment in your email.

The manual is 2,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RKL 495 DC S-Line

REMKO RKL 495 DC S-Line User Manual - German - 28 pages

REMKO RKL 495 DC S-Line User Manual - Dutch - 32 pages

REMKO RKL 495 DC S-Line User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info