726573
14
Zoom out
Zoom in
Previous page
1/28
Next page
7
"COMP. ON" key
Cooling capacity will now only be generated whilst
the compressor is active. Upon reaching the pro-
grammed target temperature, the compressor and
thus the cooling capacity will be switched of
f. The
recirculating fan however, continues to run. During
compressor operation the
7
LED illuminates.
8
Cooling mode: "AUTO, HI, MED, LO" LED
See
2
.
NOTICE!
Y
ou will achieve a pleasant room temperature if
you set the desired target temperature max. 4
to 7 °C below the outside temperature.
9
Circulated air operation: "FAN" LED
In this operating mode the air in the room is recir-
culated in the unchangeable medium stage. The
unit does not cool the air.
10
"TIMING ON" LED
The switch on timer is active.
11
"TIMING OFF" LED
The switch of
f timer is active.
12
"DRAIN WATER" display
The condensate arising will be collected in an
internal reservoir
, fed to the condenser and evapo-
rated there. The evaporated condensate will then
be fed to the outside via the exhaust air hose. If
the condensate cannot be fed away then a fault
shut-down is initiated along with an LED
12
signal-
ling this. In order to be able to use the unit again
after this fault shut-down, proceed as follows:
1. Switch the unit of
f with the "I/0" key and pull out
the power plug.
2. Place a suitable container underneath the con-
densate drain of the internal reservoir. The con-
densate drain is located on the lower centre on the
rear of the unit.
3. Pull out the stopper from the condensate drain
and collect the condensate that drains out.
4. Then insert the stopper once again.
13
Display
The programmed room temperature or the
remaining time for the timer is shown on the dis-
play
.
14
"REMOTE" IR receiver
The IR remote control should be pointed at this
receiver sensor in order to guarantee the opera-
tion.
Infrared remote control
General Information
n With the unit switched on any change to the
settings will be automatically transferred to the
room air conditioner
. The proper receipt of data
will be acknowledged with an audible "beep".
n To operate the remote control should be
pointed towards the receiver. The receipt of
data is only possible if there are no objects
between the transmitter and the receiver.
n If the system is shut down for an extended
period it is advisable to remove the batteries
from the remote control.
NOTICE!
Never use new and used batteries at the same
time, remove discharged batteries immediately
and replace these with new batteries of the pre-
scribed quality as there is a danger of dis-
charged batteries leaking.
Inserting the batteries into the remote control
Before initial commissioning, insert the supplied
batteries (2 each, type AAA) into the remote con-
trol.
1. Slide the battery compartment cover on the rear
of the remote control to open it.
2. Insert the batteries with the correct polarity
.
Observe marking in the battery compartment.
3. Close the battery compartment again.
Functions of the infra-red remote control
All settings of the unit can be implemented via the
remote control supplied. Please refer to the "Con-
trol panel" section for the functions of the keys.
The range of the remote control is ca. 5 metres.
REMKO RKL ECO series
14
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RKL 360 Eco S-Line at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RKL 360 Eco S-Line in the language / languages: English as an attachment in your email.

The manual is 2,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RKL 360 Eco S-Line

REMKO RKL 360 Eco S-Line User Manual - German - 28 pages

REMKO RKL 360 Eco S-Line User Manual - Dutch - 32 pages

REMKO RKL 360 Eco S-Line User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info