3 Design and function
Unit description
The local air conditioning unit is particularly well
suited to flexible use.
The local room air conditioner comprises a floor-
standing unit for the indoor area and an exhaust air
hose to conduct the heat away
. The indoor unit
extracts the heat from the room to be cooled by
means of an evaporator (heat exchanger) and
transfers it to the internal cooling cycle. This
releases the heat back to the outside via another
heat exchanger (condenser) by means of the flex-
ible exhaust air hose.
The condensate arising during cooling mode is
continually drained off via the condenser by means
of a condensate pump located in the unit - the con-
denser evaporates the condensate and discharges
it to the outside via the exhaust air hose.
The unit filters and dehumidifies the air thereby
creating a comfortable room climate. It works fully
automatically and offers numerous additional
options thanks to its microprocessor controller. The
operation of the unit can be conveniently operated
by means of the infra-red remote control included.
3
1
2
5
B
4
Fig. 1: Front view
B: Air outlet, recirculation
1: Recessed grip
2: Infrared receiver
3: Ventilation louvres
4: Control panel
5: Conveyor rollers
C
A
B
1
4
2
3
Fig. 2: Rear view
A: Air inlet, recirculation
B: Air inlet, exhaust air
C: Air outlet, exhaust air
1: Air filter, recirculation
2: Air filter, exhaust air
3: Exhaust air hose
4: Condensate drainage with stopper
REMKO RKL ECO series
12
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO RKL 300 Eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO RKL 300 Eco in the language / languages: English as an attachment in your email.

The manual is 2,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO RKL 300 Eco

REMKO RKL 300 Eco User Manual - German - 28 pages

REMKO RKL 300 Eco User Manual - Dutch - 32 pages

REMKO RKL 300 Eco User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info