REMKO PWN H / HK
PWN 75-3 H / HK output tables • Technical data
20 % (2 V) 40 % (4 V) 50 % (5 V) 60 % (6 V) 80 % (8 V) 100 % (10 V)
350 980 1430 1940 2950 3900
32 48 52 56 62 67
0,11 0,22 0,36 0,54 1,16 2,1
10 31 48 73 174 315
5,1 9 11,1 13,2 17,1 21,2
Utilised heating capacity (voltage)
Air flow volume m
3
/h
Sound pressure level db(A)
Current consumption A
Power consumption W
Max. casting distance (wall)
m
Heating medium
t
L1
[°C]
70 / 50 °C
+ 5
+ 10
+ 15
+ 20
55 / 45 °C
+ 5
+ 10
+ 15
+ 20
50 / 40 °C
+ 5
+ 10
+ 15
+ 20
Q
H
[kW]
t
L2
[°C]
V
[m
3
/h]
Q
H
[kW]
t
L2
[°C]
V
[m
3
/h]
Q
H
[kW]
t
L2
[°C]
V
[m
3
/h]
Q
H
[kW]
t
L2
[°C]
V
[m
3
/h]
Q
H
[kW]
t
L2
[°C]
V
[m
3
/h]
Q
H
[kW]
t
L2
[°C]
V
[m
3
/h]
6,3 59,0 0,28 14,9 50,3 0,65 19,9 46,6 0,87 25,1 43,6 1,1 34,1 39,5 1,5,0 41,7 36,9 1,83
5,8 59,1 0,25 13,5 51,3 0,59 18,1 47,9 0,80 22,8 45,1 1,0 31,0 41,3 1,36 37,8 38,9 1,66
5,2 59,0 0,23 12,2 52,1 0,54 16,3 49,0 0,72 20,5 46,5 0,9 27,8 43,1 1,22 33,9 40,9 1,49
4,5 58,7 0,21 10,8 52,8 0,47 14,4 50,1
0,63 18,1 47,9 0,8 24,5 44,8 1,08 29,9 42,9 1,31
5,1 48,8 0,45 12,2 42,2 1,07 16,4 39,4 1,44 20,8 37,0 1,82 28,4 33,8 2,49 34,8 31,6 3,05
4,6 49,1 0,40 10,9 43,2 0,95 14,6 40,6 1,28 18,5 38,5 1,62 25,3 35,6 2,21 30,9 33,7 2,70
4,0 49,3 0,35 9,5 44,1 0,83 12,8 41,8 1,12 16,2 39,9 1,42 22,1 37,3 1,93 27,0 35,7 2,36
3,5 49,4 0,30 8,2 44,9 0,72 11,0 42,9 0,96 13,8 41,3 1,21 18,9 39,1 1,65 23,1 37,7 2,02
4,6 43,8 0,40 10,8 37,9 0,94 14,5 35,4 1,27 18,4 33,2 1,61 25,0 30,4 2,18 30,7 28,5 2,68
4,0 44,0 0,35 9,5 38,8 0,83 12,7 36,6 1,11 16,1 34,7 1,41 21,9 32,1 1,91 26,8 30,5 2,34
3,4 44,1 0,30 8,1 39,7 0,71 10,9 37,7 0,95 13,7 36,1 1,20 18,7 33,9 1,63 22,8
32,5 1,99
2,8 43,9 0,24 6,7 40,5 0,59 9,0 38,8 0,79 11,3 37,5 0,99 15,4 35,6 1,35 18,8 34,4 1,64
10 % (1 V) 20 % (2 V) 30 % (3 V) 40 % (4 V) 50 % (5 V)
390 780 1170 1560 1950
24 37 45 48 52
0,08 0,11 0,15 0,22 0,36
6 10 16 31 48
2,6 5,1 7,3 9 11,1
Utilised cooling capacity (voltage)
Air flow volume m
3
/h
Sound pressure level db(A)
Current consumption A
Power consumption W
Max. casting distance (wall)
m
Cooling medium
t
L1
[°C]
7 / 12 °C
+ 25
+ 27
+ 30
+ 32
Q
K
[kW]
Q
S
[kW]
t
L2
[°C]
V
[m
3
/h]
Q
K
[kW]
Q
S
[kW]
t
L2
[°C]
V
[m
3
/h]
Q
K
[kW]
Q
S
[kW]
t
L2
[°C]
V
[m
3
/h]
Q
K
[kW]
Q
S
[kW]
t
L2
[°C]
V
[m
3
/h]
Q
K
[kW]
Q
S
[kW]
t
L2
[°C]
V
[m
3
/h]
1,10 0,75 8,90 0,19 2,10 1,61 11,3 0,36 3,11 2,60 12,5 0,53 4,81 3,87 13,2 0,82 6,69 5,18 14,2 1,15
1,32 0,84 9,10 0,23 2,54 1,77 11,9 0,44 4,11 2,98 12,6 0,71 6,22 4,30 13,9 1,07 8,45 5,74 15,0 1,45
1,69 0,96 9,40 0,29 3,54 2,12 11,9 0,61 5,75 3,47 13,3 0,99 8,37 4,96
14,9 1,44 11,2 6,60 16,2 1,92
1,96 1,05 9,60 0,34 4,26 2,35 11,9 0,73 6,86 3,79 13,7 1,18 9,89 5,42 15,5 1,70 13,2 7,20 17,0 2,26
0
10
20
30
40
50
60
0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 2,2 2,4 2,6 2,8 3 3,2 3,4
Druckverlust [kPa]
Volumenstrom [m
3
/h]
Änderung von Druckverlust über Medienvolumenstrom
Changing pressure loss via medium flow rate
Pressure loos [kPa]
Medium flow rate [m
3
/h]
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO PWN HK serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO PWN HK serie in the language / languages: English as an attachment in your email.

The manual is 2,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO PWN HK serie

REMKO PWN HK serie User Manual - German - 24 pages

REMKO PWN HK serie User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info