Group control
When installing a group
control, ensure that all units
that are connected have
the same polarity
Observe the minimum
impedance of the controller
used (see the technical data
for the controller used)
The detailed schematic
diagrams are located on
the outside of the control box
Sample calculation
Connected units: 4 x PWN 75-3 HK
Impedance of one unit: 100 kOhm
Minimum impedance of the controller provided by the customer: 1.5 kOhm
Result:
The 4 PWN 75-3 HK units can be connected to a controller in which the minimum controller impedance
(1.5 kOhm) is always reached.
1
Impedance
Complete
=
1
Impedance
Unit 1
+
1
Impedance
Unit 2
+
1
Impedance
Unit 3
+
1
Impedance
Unit n
...
+
1
Impedance
Complete
=
1
100 kOhm
+
1
100 kOhm
+
1
100 kOhm
+
1
100 kOhm
1
Impedance
Complete
=
0.04 kOhm
Impedance
Complete
=
25 kOhm
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO PWN HK serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO PWN HK serie in the language / languages: English as an attachment in your email.

The manual is 2,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO PWN HK serie

REMKO PWN HK serie User Manual - German - 24 pages

REMKO PWN HK serie User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info