The units must only be operated
in a completely assembled and
mounted condition.
The units must only be opera-
ted within the specified capacity
limits and with the approved
operating media.
Safeguards, e.g. barriers must
not be removed or rendered
inoperational.
The units must only be operated
within the specified capacity
limits and with the approved
operating media.
The air intake grilles must
always be kept free of dirt and
loose objects and the air outlet
must not be closed.
Never insert foreign objects into
the unit.
The units must not be exposed
to a direct jet of water.
Do not operate the units in wet
areas with high humidity (e.g.
car wash).
All electric cables of the units
must be protected against da-
mage e.g. animals, etc.
Unit description
These units are stationary, indirect-
ly recirculated air cooling/heating
units with copper/aluminium fin
heat exchangers for connection to
a pumped cold/ hot water system
up to max. 90°C.
The units are in an exclusive de-
sign, compact, universal and are
easy to install and service.
NOTE
Perfect functioning of the units
is only ensured when the flow
temperature at the unit inlet
and the pump capacity cor-
respond to the selected unit
classification.
The inner supporting unit con-
struction is made of galvanised
sheet steel.
The heat exchangers have copper
tubes with aluminium fins.
For removal of the produced
condensate in cooling operation,
a ready to connect condensate
pump is provided.
For an optimal air flow, individually
adjustable louvres are provided at
the top of the housing and fully
adjustable louvre segments are
provided at the bottom.
The air discharge direction (hori-
zontal or vertical) can be individu-
ally adjusted to suit the local requi-
rements by changing the direction
of rotation of the fan.
The plastic housing can be deta-
ched completely from the sup-
porting lower housing part by
removing the securing clip. The
integrated securing strips prevent
the cover from falling.
The plastic housing of the units is
made of self-extinguishing material
(fire class V-0).
The heaters comply with the basic
health and safety requirements of
the pertinent EU regulations and
are easy to operate.
The units are suitable for heating/
cooling rooms with high or low
ceilings and where special impor-
tance is attached to exclusivity.
For example in large rooms such
as:
Exhibition halls
Sales rooms
Shopping centres
Business premises
Warehouses
Production halls
Foremen’s offices
Large entrance areas
The units must be mounted hori-
zontally on ceilings or roof struc-
tures.
The units are fitted with an aero-
dynamic, powerful two-speed axial
flow fan with 400V/50Hz external
rotor motor as standard.
Help save on energy consump-
tion in stand-by mode! If the
device, system or component
is not in use, we recommend
disconnecting the power sup-
ply. Components with a safety
function is excluded from our
recommendation!
TIP
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for REMKO PWL serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of REMKO PWL serie in the language / languages: English as an attachment in your email.

The manual is 1,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of REMKO PWL serie

REMKO PWL serie User Manual - German - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info